Rsvp-Te; Service Manager; Sonet; Src Software And Sdx Software - Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - RELEASE NOTES 2010-11-09 Release Note

Software for e series broadband services routers
Table of Contents

Advertisement

RSVP-TE

Service Manager

SONET

SRC Software and SDX Software

Stateful SRP Switchover (High Availability) and IP Tunnels

Copyright © 2010, Juniper Networks, Inc.
After stateful SRP switchover, forwarding of VPN traffic might not resume if the core
interface that carries an MPLS base tunnel with LDP over RSVP-TE flaps (constantly
goes up and down). [Defect ID 182019]
After you activate an independent IPv6 service and issue either of the following
commands on the default virtual router or any other virtual router, except the one on
which the subscriber session is active, no output is displayed in the CLI interface:
[Defect ID 181929]
 show service-management subscriber-session subscriberName interface
interfaceType interfaceSpecifier
 show service-management subscriber-session subscriberName interface
interfaceType interfaceSpecifier service-session serviceName
This problem also occurs when a subscriber is authenticated using a RADIUS
server for a combined IPv4 and IPv6 service in a dual stack.
Work-around: To avoid this problem, use the show service-management
owner-session ownerName ownerId command to display subscriber session
information based on the session owner, instead of the show service-management
subscriber-session subscriberName interface interfaceType command to display
details on subscriber sessions.
You cannot use the highest sensitivity bit-error rate setting (a value of 9) associated
with APS/MSP alarm when you issue the threshold sd-ber command to configure a
cOCx/STMx line module with cOC12-APS-capable IOAs. [Defect ID 72861]
Work-around: Use only a value in the range 5–8 when you issue the threshold sd-ber
command for this module combination, as in the following example:
host1(config)#controller sonet 2/1
host1(config-controll)#aps group boston
host1(config-controll)#aps protect
host1(config-controller)#threshold sd-ber 6
When multiple IPv6 interfaces are configured with policies attached from SRC, only
some of the IPv6 interfaces have the policies attached. [Defect ID 179498]
Changing the SSCC status (enable/disable) while IPv6 interfaces are configured
might cause the SRP to reset. [Defect ID 179537]
A packet loss sometimes occurs during stateful SRP switchover when you use the
ping command on a router that is configured for OSPF graceful restart, and is
connected to a helper router in the OSPF IPv6 broadcast network and another helper
router in the OSPF IPv6 backbone area. [Defect ID 181470]
 ERX7xx model, ERX14xx model, or ERX310 router:
Release 11.3.0
Known Problems and Limitations
51