DA17 /user and /password switches required for this configuration
Source: GroupWise engine; Post Office Agent.
Explanation: The
remote server.
Possible Cause: The POA needs to log in to a remote server where a document storage area is
located, but it does not have the necessary user and password information to
log in with.
Action: See
"Post Office
Action: In ConsoleOne, specify the login information in the Remote File Server
Settings box on the Post Office Settings page of the Post Office object.
Possible Cause: You have renamed the server where a document storage area is located. The
POA can no longer access the original document storage area location, so the
POA cannot start.
Action: First, provide the new location of the document storage area. See
Document Storage
Administration
Next, start the POA using the /noconfig, /user, and
POA can start and process the administrative message containing the new
storage location without accessing the old storage location. Finally, exit, then
restart the POA with its typical configuration.
7.19 DB0x Errors
"DB01 Operation cancelled" on page 119
"DB02 Database access error" on page 120
"DB03 Operation pending; cannot modify" on page 120
"DB04 Owner not valid user" on page 120
"DB05 Invalid path" on page 120
"DB08 Non-unique name" on page 120
"DB09 User owns resource" on page 121
"DB0A Record not found" on page 121
"DB0B Required field empty" on page 121
"DB0C Cannot close database" on page 122
"DB0E Insufficient memory to initialize database" on page 122
"DB0F Domain not found" on page 122
DB01 Operation cancelled
Source: GroupWise engine; administration engine.
Explanation: Operation cancelled.
Possible Cause: Operation cancelled by user.
/user
and
/password
switches are required when the POA must log into a
"Using POA Startup
Switches" and
Agent" in the
GroupWise 7 Administration
Area" in
"Libraries and
Guide.
"Installing and Starting the
Guide.
Documents" in the
GroupWise 7
/password
switches so the
POA" in
"Moving a
Dxxx Engine Error Codes 119
Need help?
Do you have a question about the GROUPWISE 7 - TROUBLESHOOTING 1 and is the answer not in the manual?