Wiring and Installation

Troubleshooting

The following table gives solutions to the most common installation problems.
Solutions to Common Installation Problems
Problem
Presets fade erratically.
Panel LED stays on.
Cannot select zones 1 - 12.
No operation.
All lights stay On.
In the Preset Recall Mode, Presets can be recalled,
but Up and Down arrows do not work.
12
Resolution
Check phasing.
Check the PROlink wiring, Pack number, and dimmer
Pack settings.
Check Pack number and mode settings.
Check PROlink wiring.
Check dimmer DIP switch settings and disconnect/
reconnect AXlink or RS232 control.
Check Pack numbers. Verify that Packs are set for 1
and 2