Wiring and Installation
Troubleshooting
The following table gives solutions to the most common installation problems.
Solutions to Common Installation Problems
Problem
Presets fade erratically.
Panel LED stays on.
Cannot select zones 1 - 6.
No operation.
All lights stay On.
In Preset Recall Mode, Presets can be recalled, but
the Up and Down buttons (pushbuttons 14 and 15) do
not work.
12
Resolution
Check phasing.
Check the PROlink wiring, Pack number, and dimmer
Pack settings.
Check Pack number and mode settings.
Check PROlink wiring/power connections.
Check dimmer DIP switch settings and disconnect/
reconnect PROlink.
Check Pack numbers. Verify that Packs are set for
1 - 10.