17
. IGNITION SYSTEM
CDI UNIT
RESISTANCE INSPECTION
Measure the resistance between the terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
• Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing. Use of an
improper tester in an improper range
may give false readings.
• Use a Sanwa Electric Tester (07308-
0020000) or Kowa Electric Tester
(TH-5H).
• In this table, "Needle swings then
returns" indicates that there is a
charging current applied to a condenser.
The needle will then remain at "
unless the condenser is discharged.
x
Use the
KW range for the Sanwa Tester.
x
Use the
100W range for the Kowa Tester.
(+)Probe
(Black/White)
(-)Probe
SW
(Black/White)
EXT
(Black/Red)
PC
(Blue/Yellow)
E Å Ç
(Green •
Green/White)
IGN
(Black/Yellow)
17-5
Unit: KW
SW
EXT
(Black/Red)
1-10
50-90
30-100
5-20
1-10
Å
E
(Green)
Ç
E
(Green/White)
"
E Å Ç
PC
(Green •
(Blue/Yellow)
Green/White)
100-200
250-450
5-40
GRAND DINK 125/150
IGN
PC
(Black/Yellow)
(Blue/Yellow)
EXT
(Black/Red)
IGN
(Black/Yellow)
20-80
SW
(Black/White)