Float Level Inspection; Vacuum Chamber Assembly - KYMCO GRAND DINK 125 Service Manual

Hide thumbs Also See for GRAND DINK 125:
Table of Contents

Advertisement

13
. FUEL SYSTEM/CARBURETOR/
FUEL PUMP/ FUEL TANK

FLOAT LEVEL INSPECTION

Measure the float level at the location of the
main jet (just contacting the float valve).
Float Level: 18.5±1.0mm
Replace the float if the level is incorrect.
Check the operation of the float and then
reinstall the float chamber.

VACUUM CHAMBER ASSEMBLY

First install the jet needle and spring into the
vacuum chamber and then install the needle
holder.
Install the vacuum piston into the carburetor
body.
• Align the hole in the diaphragm with
the hole in the carburetor body.
Install the spring.
Install the vacuum chamber cover and tighten
it with the two screws.
• Be careful not to let the diaphragm slip.
• If the diaphragm cannot be positioned
correctly because of expansion, dry the
diaphragm before installation.
GRAND DINK 125/150
Float
Vacuum Piston
Jet Needle
Spring
Vacuum Piston
Spring
Needle Holder
Diaphragm
13-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grand dink 150

Table of Contents