Server specifications
In this section
Server specifications ............................................................................................................................. 120
Environmental specifications .................................................................................................................. 120
Server specifications
The following information pertains to the rack configuration.
Specification
Dimension
Height
Depth
Width
Weight (maximum)
Weight (no drives installed)
Input requirement
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Power supply output
* 100 to 127 VAC is required for 8 A; 200 to 240 VAC is required for 4 A.
Environmental specifications
Specification
Temperature range*
Operating
Shipping
Maximum wet bulb temperature
Value
26.67 cm (10.5 in)
67.31 cm (26.5 in)
44.45 cm (17.5 in)
63.5 kg (140 lb)
41.28 kg (91 lb)
100-127 VAC
200 - 240 VAC
50 Hz - 60 Hz
@ 100VAC - 12 A
@ 200VAC - 8 A
@100 VAC - 1161 W
@200 VAC - 1598 W
@100 VAC - 3960
@200 VAC - 5450
910 W (low line)
1300 W (high line)
Value
—
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
28°C (82.4°F)
Server specifications 120