When the system maintenance switch position 6 is set to the On position, the system is prepared to erase
all system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly
configure the server or data loss could occur.

System LEDs and internal health LED combinations

When the internal health LED on the front panel illuminates either flashing amber or flashing red, the
server is experiencing a health event. Combinations of illuminated system LEDs and the internal health LED
indicate system status.
NOTE: The system management driver must be installed for the internal system health LED to provide pre-
failure and warranty conditions.
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may
report server status differently than the health LEDs because the software tracks additional system
attributes.
System LED and color
Processor failure,
socket X (amber)
Processor failure,
socket X (amber)
PPM failure, slot X
(amber)
DIMM failure, slot X
(amber)
DIMM failure, slot X
(amber)
DIMM bank error (all
slots in one bank,
amber)
DIMM failure (all
slots, amber)
Description
Function
Invalid
Off = Normal
configuration
On = ROM treats system
configuration as invalid
Reserved
Reserved
Internal health LED
color
Flashing red
Flashing amber
Flashing red
Flashing red
Flashing amber
Flashing red
Flashing red
Status
One or more of the following conditions may exist:
Processor in socket X has failed.
Processor X is not installed in the socket.
ROM detected a failed processor during POST.
Processor in socket X is in a pre-failure condition.
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
DIMM in slot X has failed.
DIMM has experienced a multi-bit error.
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
The bank is not populated entirely or DIMMs do not all
match within the bank.
No valid or usable memory is installed in the system.
The banks are not populated in the correct order.
Server component identification 14