Dell PowerVault MD3260 Cli Manual page 223

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3260:
Table of Contents

Advertisement

set virtualDisk["7"] mediaScanEnabled=false;
set virtualDisk["7"] consistencyCheckEnabled=false;
set virtualDisk["7"] modificationPriority=high;
The command in this example, like the create virtualDisk command in the previous example, creates a new
virtual disk. The significant difference between these two examples is that this example shows how you can define
specific physical disks to include in the virtual disk. To find out what physical disks are available in a storage array, run
the show storageArray profile command.
The following syntax is the general form of the create virtualDisk command shown in the previous example:
create virtualDisk raidLevel=(0 | 1 | 5 | 6)
userLabel="virtualDiskName" physicalDisks=
(enclosureID0,slotID0... enclosureIDn,slotIDn)
[capacity=virtualDiskCapacity | owner=(0 | 1) |
segmentSize=segmentSizeValue]
[enclosureLossProtect=(TRUE | FALSE)]
223