Dell PowerVault MD3260 Cli Manual page 108

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3260:
Table of Contents

Advertisement

You do not need to enter a value for the
enter a value, the RAID controller module firmware uses the
value. Entering a value for the
segmentSize parameter does not cause an error. The value that you enter for the cacheReadPrefetch parameter or the
segmentSize parameter takes priority over the value for the usageHint parameter.
Segment Size
The size of a segment determines how many data blocks that the RAID controller module writes on a single physical disk
in a virtual disk before writing data on the next physical disk. Each data block stores 512 bytes of data. A data block is
the smallest unit of storage. The size of a segment determines how many data blocks that it contains. For example, an 8
KB segment holds 16 data blocks. A 64 KB segment holds 128 data blocks.
When you enter a value for the segment size, the value is checked against the supported values that are provided by the
RAID controller module at run time. If the value that you entered is not valid, the RAID controller module returns a list of
valid values. Using a single physical disk for a single request leaves other physical disks available to simultaneously
service other requests.
If the virtual disk is in an environment where a single user is transferring large units of data (such as multimedia),
performance is maximized when a single data transfer request is serviced with a single data stripe. A data stripe is the
segment size that is multiplied by the number of physical disks in the disk group that are used for data transfers. In this
case, multiple physical disks are used for the same request, but each physical disk is accessed only once.
For optimal performance in a multiuser database or file system storage environment, set your segment size to minimize
the number of physical disks that are required to satisfy a data transfer request.
Security Type
The
securityType parameter is valid for physical disks that are capable of selfencrypting disk (SED). With SED, the RAID
controller module firmware can create a key and activate the physical disk security feature. The physical disk security
feature encrypts data as the data is written to the physical disk and decrypts the data as the data is read from the
physical disk. Without the key created by the RAID controller module, the data written to the physical disk is
inaccessible.
securityType parameter to capable or enabled, you must create a storage array security key. Use
Before you can set the
the create storageArray securityKey command to create a storage array security key. The following
commands are related to the security key:
create storageArray securityKey
set storageArray securityKey
start secureErase (physicalDisk | physicalDisks)
enable diskGroup [diskGroupName] security
Enclosure Loss Protection and Drawer Loss Protection
For enclosure loss protection to work, each physical disk in a disk group must be in a separate enclosure. If you set the
enclosureLossProtect parameter to TRUE and have selected more than one physical disk from any one enclosure, the
storage array returns an error. If you set the
operations, but the disk group that you create might not have enclosure loss protection. Enclosure loss protection is not
valid when you create virtual disks on existing disk groups.
drawerLossProtect parameter defines if data on a virtual disk is accessible if a drawer fails. When you assign the
The
physical disks, if you set the
one drawer, the storage array returns an error. If you set the
performs operations, but the disk group that you create might not have drawer loss protection. You must set the
enclosureLossProtect parameter and the drawerLossProtect parameter to the same value. Either both the parameters
must be TRUE or both must be FALSE. If the
are set to different values, the storage array returns an error.
108
cacheReadPrefetch parameter or the segmentSize parameter. If you do not
usageHint parameter and a value for the cacheReadPrefetch parameter or a value for the
enclosureLossProtect parameter to FALSE, the storage array performs
drawerLossProtect parameter to TRUE and select more than one physical disk from any
enclosureLossProtect parameter and the drawerLossProtect parameter
usageHint parameter with fileSystem as the default
drawerLossProtect parameter to FALSE, the storage array

Hide quick links: