Enterprise-Specific Invalid Attachment Trap; Enterprise-Specific Threshold Alert Trap; Enterprise-Specific Fru Traps - McDATA StorageWorks 64 - SAN Director Switch Manual

E/os snmp
Hide thumbs Also See for StorageWorks 64 - SAN Director Switch:
Table of Contents

Advertisement

McDATA SNMP Support
2

Enterprise-specific Invalid Attachment Trap

Binding
OID
1
1.3.6.1.4.1.289.2.1.1.2.4.1.1.4.port_number+1
fcEosPortAttachedWWN.port_number+1

Enterprise-specific Threshold Alert Trap

Binding
OID
1
1.3.6.1.4.1.289.2.1.1.2.3.1.1.1.port_number+1
fcEosPortIndex.port_number+1
2
1.3.6.1.4.1.289.2.1.1.2.6.1.1.1.threshold_number
fcEosTAIndex.threshold_number

Enterprise-specific FRU Traps

E/OS SNMP Support Manual
2-8
This trap is sent when an invalid attachment occurs (a device is
attached, with a WWN specifically disallowed by port binding).
There is 1 variable binding.
This trap is sent when port traffic exceeds a specified threshold.
There are 2 variable bindings.
The enterprise specific FRU traps (FRU removed, FRU active, FRU
backup, FRU update, FRU failed: type codes 5-9) share the same
bindings. There are 4 variable bindings for these traps:
Value
WWN of invalid attached device. See
definition for fcEosPortAttachedWWN.
Value
Port number of port with threshold alert.
The index of the threshold which was
triggered.