McDATA StorageWorks 64 - SAN Director Switch Manual page 100

E/os snmp
Hide thumbs Also See for StorageWorks 64 - SAN Director Switch:
Table of Contents

Advertisement

McDATA SNMP Support
2
Fx_Port Error Table
fcFxPortErrorFxPortIndex
FcFxPortLinkFailures
FcFxPortSyncLosses
E/OS SNMP Support Manual
2-82
Access
R
Description
This object identifies the BB_Credit model used by the Fx_Port. The
regular model refers to the Buffer-to-Buffer flow control mechanism
defined in FC-PH [1] is used between the F_Port and the N_Port. For
FL_Ports, the Alternate Buffer-to-Buffer flow control mechanism as
defined in FC-AL [4] is used between the FL_Port and any attached
NL_Ports.
This is fixed at regular(1).
A table that contains one entry for each Fx_Port, counters that record
the numbers of errors detected.
Type
FcFeFxPortIndex
Provided By
SNMP
Access
R
Description
This object identifies the Fx_Port within the module. This number
ranges from 1 to the value of
associated module. The value remains constant for the identified
Fx_Port until the module is re-initialized.
Type
Counter
Provided By
PSCC
Access
R
Description
The number of link failures detected by this Fx_Port.
Type
Counter
Provided By
PSCC
Access
R
Description
The number of loss of synchronization detected by the Fx_Port.
fcFeModulePortCapacity
for the

Advertisement

Table of Contents
loading

Related Products for McDATA StorageWorks 64 - SAN Director Switch

Table of Contents