Det-Tronics ATX10 Instructions Manual

Det-Tronics ATX10 Instructions Manual

Acoustic detector, sensor, transmitter

Advertisement

Quick Links

Instructions
FlexSonic
Acoustic Detector
AC100 Sensor
ATX10 Transmitter
4.4
Rev: 12/19
95-8657

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATX10 and is the answer not in the manual?

Questions and answers

Summarization of Contents

FlexSonic Detector Specifications
Certification Details
List of certifications and approvals for the device.
Electromagnetic Compatibility Standards
EMC standards compliance for the detector.
ATX10 Transmitter Specifics
Current Output Signal Interpretation
Explanation of 4-20 mA output signals and their meanings.
ATX10 LED Status Indicators
Meaning of the ATX10 transmitter's LED status lights.
ATX10 Transmitter Operation
ATX10 Operating Power Requirements
Power supply requirements and range for the detector system.
ATX10 Transmitter LEDs Explained
Status indications provided by the ATX10 transmitter LEDs.
Acoustic Integrity Check (AIC) Functionality
Automatic AIC Self-Test Procedure
Automatic periodic self-test procedure for the sensor.
Manual AIC Self-Test Activation
Manual initiation and reset of the sensor self-test.
Detector Operation Modes
Basic Mode Configuration
Configuration and settings for the detector's Basic Mode.
Profile Mode Configuration
SD Memory Module Operation
Functionality and data files of the SD Memory Module.
Important Safety Notes and Precautions
Critical Installation Cautions
Important warnings and precautions during installation.
Power Supply and Wiring Requirements
Sensor Installation Procedures
Procedures for physically installing the AC100 Acoustic Sensor.
Detector Startup Sequence
Basic Mode Configuration via HART
Configuring the detector for Basic Mode operation via HART.
Profile Mode Detector Configuration
Profile-Level Mode Settings
Using fixed thresholds with additional settings in Profile Mode.
Profile-Learn Mode Operation
Utilizing the Learn Function to adapt to background acoustics.
General Application Information
Identifying Nuisance Sources
Identifying and mitigating false alarms from environmental noise.
Maintenance of FlexSonic Detector
Cleaning the AC100 Sensor
Instructions for cleaning the AC100 sensor cover and foam insert.
Troubleshooting Detector Faults
Troubleshooting Guide for Faults
A guide correlating fault indications with corrective actions.
ATEX Approval Description
ATEX Special Conditions for Safe Use
Specific safety conditions mandated by ATEX for installation.
IECEx Approval Description
IEC Special Conditions for Safe Use
Specific safety conditions mandated by IECEx for installation.
Approved Adjoining Assemblies
Direct Connection Diagram
Diagram for AC100 directly connected to ATX10.
Remote Sensor Connection Diagram
Diagram for AC100 connected via STB to ATX10.

Table of Contents