Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Det-Tronics Manuals
Security Sensors
AC100
Instructions manual
Det-Tronics AC100 Instructions Manual
Acoustic detector, sensor, transmitter
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
page
of
38
Go
/
38
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Overview
Features
Benefits
Specifications
Description
Ac100
Atx10
Operation
Basic Mode
Profile Mode
Data Storage/Management
Important Safety Notes
Installation
Sensor Termination Box
Grease/Lubrication
Protection against Moisture Damage
Foam Insert
Identification of Detector Mounting Locations
Detector Coverage
Power Supply Requirements
Wiring Cable Requirements
External Bonding
Shield Connections
Sensor Installation
Wiring Procedure
Startup
Basic Mode
Profile Mode
Prealarm Configuration
Password Protection
General Application Information
Nuisance Sources
Friendly Leaks
Maintenance
Routine Inspection
Cleaning
Troubleshooting
Device Repair and Return
Ordering Information
Replacement Parts
Accessories
Assistance
Appendix A - Fm Approval Description
Appendix B - Csa Certification Description
Appendix C - Atex Approval Description
APPENDIX D - Iecex APPROVAL DESCRIPTION
Appendix E - Maritime Approval
Appendix F - Additional Approvals
Appendix G - Approved Adjoining Assemblies
Advertisement
Quick Links
Download this manual
Instructions
FlexSonic
™
Acoustic Detector
AC100 Sensor
ATX10 Transmitter
4.4
Rev: 12/19
95-8657
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the AC100 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Det-Tronics AC100
Security Sensors Det-Tronics ATX10 Instructions Manual
Acoustic detector, sensor, transmitter (38 pages)
Security Sensors Det-Tronics X Series Instructions Manual
Enhanced flame inspector software for use with det-tronics flame detectors (20 pages)
Security Sensors Det-Tronics FlexSonic Instructions Manual
Acoustic detector, sensor, transmitter (38 pages)
Security Sensors Det-Tronics OPECL Instructions Manual
Infrared hydrocarbon gas detector open path eclipse (24 pages)
Security Sensors Det-Tronics Protect IR X3302 Instructions Manual
Multispectrum ir flame detecto (25 pages)
Security Sensors Det-Tronics PIRECL Instructions Manual
Infrared hydrocarbon gas detector pointwatch eclipse (69 pages)
Security Sensors Det-Tronics LS2000 Instructions Manual
Line of sight infrared hydrocarbon gas detector (46 pages)
Security Sensors Det-Tronics X5200 Instructions Manual
Uvir flame detector (34 pages)
Security Sensors Det-Tronics X3301 Instructions Manual
Protect-ir multispectrum ir flame detector with pulse output (27 pages)
Security Sensors Det-Tronics X3301 Instructions Manual
Multispectrum ir flame detector (43 pages)
Security Sensors Det-Tronics Eagle Quantum EQ2200UVHT Installation Manual
For use with c7050b continuous duty high temperature uv flame detector (8 pages)
Security Sensors Det-Tronics X3301 Instructions Manual
Multispectrum ir flame detector with pulse output (39 pages)
Security Sensors Det-Tronics X5200 Instructions Manual
Uvir flame detector with pulse output (34 pages)
Security Sensors Det-Tronics Open Path Eclipse Instructions Manual
Infrared hydrocarbon gas detector (49 pages)
Security Sensors Det-Tronics X Series Addendum
Flame detectors with pulse output (16 pages)
Security Sensors Det-Tronics Protect-IR X3301 Instructions Manual
Multispectrum ir flame detector (28 pages)
Summarization of Contents
Instructions Overview
FlexSonic Detector Overview
Provides a general description of the FlexSonic Acoustic Detector's functionality and purpose.
FlexSonic Detector Features
Lists the key capabilities and attributes of the FlexSonic Acoustic Detector.
FlexSonic Detector Benefits
Highlights the advantages and value propositions of using the FlexSonic Acoustic Detector.
FlexSonic Detector Specifications
Operating Voltage and Power Consumption
Details the electrical requirements including voltage range and power draw for the detector components.
Environmental and Physical Specifications
Covers temperature, humidity, ingress protection, enclosure material, and dimensions.
Certifications and Approvals
Lists the various certifications and standards the detector complies with.
AC100 Acoustic and AIC Specifications
Details the acoustic performance and self-diagnostic capabilities of the AC100 sensor.
ATX10 Transmitter Specifications
Outlines specific electrical outputs, loop resistance, and wiring for the ATX10 transmitter.
ATX10 Transmitter Operation
ATX10 Operating Power and LEDs
Explains the power supply requirements and the meaning of the ATX10's status LEDs.
ATX10 Magnetic Switches and Output
Describes the function of magnetic switches and the 4-20mA output signal interpretation.
Acoustic Integrity Check (AIC)
Automatic AIC Functionality
Details the automatic periodic self-test of the acoustic sensor's integrity.
Manual AIC Test Procedure
Explains how to manually initiate an acoustic integrity test and interpret results.
Operation Modes and Data Management
Event Logging and Removable Memory
Describes how events are logged and the use of the removable SD memory card.
Basic Mode Operation
Covers the configuration and functionality of the basic detection mode.
Profile Mode Operation
Explains the advanced profile mode, including learn function and settings.
Flash and SD Memory Data Storage
Details the types of data stored in flash memory and the SD memory module.
SD Memory Module Management
Memory Module Initialization Flow
Illustrates the process for initializing and synchronizing the memory module.
SD Memory Module Removal and Replacement
Provides instructions for safely removing and installing the SD memory module.
Important Safety Notes
General Safety Warnings and Liabilities
Covers essential safety precautions, warnings, and liability information for the user.
Installation Guidelines
Provides essential instructions and requirements for installing the detector.
Grounding and Intrinsic Safety
Specifies requirements for electrical grounding and intrinsic safety barriers.
Installation Codes and Component Notes
Covers adherence to local codes, adapter prohibition, and shipping tape removal.
Sensor Termination Box (STB)
Describes the function and use of the Sensor Termination Box.
Installation Procedures
Lubrication and Moisture Protection
Details lubrication best practices and precautions against moisture ingress.
Foam Insert Installation
Instructions for installing the optional foam insert for sensor protection.
Detector Mounting Location Guidance
Recommendations for positioning the detector for optimal performance.
Detection Coverage
Acoustic Signal Coverage Explanation
Explains how the detector covers areas and factors affecting detection range.
Wiring and Sensor Installation
Power Supply and Bonding Requirements
Details power supply needs, external bonding, and shield connection procedures.
3/4" NPT Sensor Installation
Step-by-step guide for installing the 3/4" NPT sensor model.
M25 Sensor Installation
Step-by-step guide for installing the M25 sensor model.
Wiring Procedures and Diagrams
Cable Termination and Grounding
Instructions for proper cable termination, grounding, and HART communication requirements.
Wiring Diagrams Overview
Refers to various wiring configurations shown in figures for different setups.
Startup and Configuration
Power-Up Fault Handling
Explains the initial fault indication upon powering up the ATX10.
Basic Mode Configuration
Guides the user through setting up the detector in Basic Mode using HART.
Profile Mode Configuration
Details configuration options for Profile Mode, including Level and Learn.
Profile Mode Pre-Alarm Setup
Instructions for configuring the pre-alarm functionality within Profile Mode.
Password Protection
Configuration Access Control
Explains how to use passwords to restrict access to critical settings.
General Application Information
Identifying Nuisance Sources
Discusses common sources of false alarms and how to manage them.
Detecting Friendly Leaks
Addresses the detection of non-hazardous gas leaks and discrimination.
Maintenance Procedures
Routine Inspection and Cleaning
Outlines periodic inspection of the sensor cover and cleaning instructions.
Troubleshooting Guide
Fault Indications and Corrective Actions
Provides a guide to identifying faults and the recommended corrective steps.
Device Management and Support
Repair and Return Process
Details the procedure for returning devices for repair and obtaining an RMI number.
Ordering Information and Kits
Information on how to order the detector system and available kits.
Technical Assistance Contact
Provides contact details for customer service and technical support.
Appendix A: FM Approval
AC100 FM Approval Details
Specifies the FM approval classifications and conditions for the AC100 sensor.
ATX10 FM Approval Details
Specifies the FM approval classifications and conditions for the ATX10 transmitter.
Appendix B: CSA Certification
AC100 CSA Certification Details
Lists the CSA certification classifications and applicable standards for the AC100.
ATX10 CSA Certification Details
Lists the CSA certification classifications and applicable standards for the ATX10.
Appendix C: ATEX Approval
AC100 ATEX Approval Details
Details the ATEX approval classifications and requirements for the AC100 sensor.
ATX10 ATEX Approval Details
Details the ATEX approval classifications and requirements for the ATX10 transmitter.
ATEX Special Conditions for Safe Use
Outlines specific safety conditions required for ATEX installations.
Appendix D: IECEx Approval
AC100 IECEx Approval Details
Specifies the IECEx approval classifications and conditions for the AC100 sensor.
ATX10 IECEx Approval Details
Specifies the IECEx approval classifications and conditions for the ATX10 transmitter.
IECEx Special Conditions for Safe Use
Outlines specific safety conditions required for IECEx installations.
Appendix E: Maritime Approval
DNV GL Maritime Approval
Details the DNV GL approval for maritime installations and location classes.
Maritime Installation Line Filter
Specifies the requirement for a line filter in maritime installations.
Appendix F: Additional Approvals
Russia & Kazakhstan EAC Approval
Details conformity certificates for Russia and Kazakhstan (EAC).
Appendix G: Adjoining Assemblies
Direct Connection Assemblies
Shows configurations for direct connection of AC100 to ATX10.
Remote Sensor Assemblies
Illustrates configurations for remote AC100 sensor connection via STB.
Universal Display Assemblies
Shows configurations for AC100/ATX10 with a universal display unit.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the AC100 and is the answer not in the manual?
Questions and answers