AZ59.
IRET under Certain Conditions May Cause an Unexpected Alignment
Check Exception
In IA-32e mode, it is possible to get an Alignment Check Exception (#AC) on the IRET
Problem:
instruction even though alignment checks were disabled at the start of the IRET. This
can only occur if the IRET instruction is returning from CPL3 code to CPL3 code. IRETs
from CPL0/1/2 are not affected. This erratum can occur if the EFLAGS value on the stack
has the AC flag set, and the interrupt handler's stack is misaligned. In IA-32e mode,
RSP is aligned to a 16-byte boundary before pushing the stack frame.
In IA-32e mode, under the conditions given above, an IRET can get a #AC even if
Implication:
alignment checks are disabled at the start of the IRET. This erratum can only be
observed with a software generated stack frame.
Workaround: Software should not generate misaligned stack frames for use with IRET.
Status:
For the steppings affected, see the Summary Tables of Changes.
AZ60.
Thermal Interrupts are Dropped During and While Exiting Intel® Deep
Power-Down State
Thermal interrupts are ignored while the processor is in Intel Deep Power-Down State as
Problem:
well as during a small window of time while exiting from Intel Deep Power-Down State.
During this window, if the PROCHOT signal is driven or the internal value of the sensor
reaches the programmed thermal trip point, then the associated thermal interrupt may
be lost.
In the event of a thermal event while a processor is waking up from Intel Deep Power-
Implication:
Down State, the processor will initiate an appropriate throttle response. However, the
associated thermal interrupt generated may be lost.
Workaround: None identified.
Status:
For the steppings affected, see the Summary Tables of Changes.