Get Unit Configuration - Lexicon RV-8 V1.10 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-7 Manual

Serial communications protocol definition
Table of Contents

Advertisement

Lexicon, Inc.
RV-8 Serial Communications Protocol
7.3.15.1 Command Packet Description
Application Header:
Command
MC_CMD_SET_SYS_PARAM_VALUE_BY_ID_NO_RUN 0x37
Data Count 24
Application Data:
Data[0]
ParamId(LSB)
Data[1]
ParamId(MSB)
Data[2]
ParamType
Data[3-23] Value[0 -20]
7.3.15.2 Data Description
Same as
Paragraph 7.3.14.2

7.3.16 Get Unit Configuration

Request to RV-8 for its current unit configuration. RV-8 will respond with "Unit Configuration Packet".
The HOST should use this information to determine if any information saved by the HOST is current.
7.3.16.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
© 2005 Lexicon, Inc. All rights reserved.
MC_CMD_GET_CONFIG
0
N/A
Printed on: 07/26/05
0x18
nn
nn
nn
nn nn
nn...
0x38
0x00
23 of 72