System Messages - Furuno FA Manual

Marine radar/arpa far-28x7 series; far-21x7 series; far-21x7-bb series
Table of Contents

Advertisement

6. MAINTENANCE, TROUBLESHOOTING
6.9

System Messages

This sections provides all the error messages which may appear on the display
screen.
Message
Signal Missing
DATUM
Continuous
GYRO
Continuous
LOG
Continuous
EPFS
Continuous
TRIGGER
Continuous
VIDEO
Continuous
AZIMUTH
Continuous
HEADLINE
Continuous
ARPA Alarm
COLLISION
Continuous
GUARD
Continuous
LOST
Beep
ARPA SYSTEM
Continuous
ERROR
TARGET-FULL
Continuous
(AUTO+MAN)
TARGET-FULL
Continuous
(AUTO)
TARGET-FULL
Continuous
(MAN)
AIS Alarms
COLLISION
Continuous
LOST
Beep
ARPA FUSION
Beep
RECEIVE
None
GUARD
Continuous
CPA/TCPA
Continuous
TARGET-FULL
None
AIS ALARM
Continuous
(Continued on next page)
6-12
System messages
Alarm
Wrong chart datum (only WGS84 is permitted)
No bearing data
No speed log data
No position data
No trigger signal (antenna)
No video signal
No antenna rotation signal
No heading signal
A tracked target's CPA and TCPA fulfill criteria for
collision course
A tracked target is present in the guard zone
A tracked target becomes a lost target
No status data from ARPA
Capacity for automatic and manually acquired targets
has been reached
Capacity for automatically acquired targets has been
reached
Capacity for manually acquired targets has been
reached
A tracked target's CPA and TCPA fulfill criteria for
collision course
A tracked target becomes a lost target
ARPA and AIS target combined
Not receiving AIS data from own AIS (VDO message)
Tracked target is inside the guard zone
CPA/TCPA cannot be calculated; Ground data (VTG, L/L)
no present
Capacity for AIS target has been reached
Alarm received from AIS transponder
Meaning