System Configuration - Furuno FAR-2018-MARK-2 Operator's Manual

Hide thumbs Also See for FAR-2018-MARK-2:
Table of Contents

Advertisement

SYSTEM CONFIGURATION

IMO-type radar(s) must be interconnected to the following type approved sensors.
For other radar types, it is recommended to connect the following type approved sensors.
• EPFS meeting the requirements of the IMO resolution MSC.112(73).
• Gyrocompass (or equivalent devices) meeting the requirements of the IMO resolution A.424(XI).
• SDME meeting the requirements of IMO resolution MSC.96(72).
The radar may be interconnected via HUB-3000 to other FURUNO processing units having
approved LAN ports.
Note: Basic configuration is shown with a solid line. For footnotes, see "Notes" on page xxii.
X-band (TR-UP, CF Antenna)
for FAR-2228-NXT(-BB)/2328-NXT,
600 W (500 W for a Japanese flag vessel)
(w/ Performance Monitor PM-32B*
100-115/220-230 VAC
1ø, 50-60 Hz (for de-icer)
Control Unit
RCU-016
100-230 VAC
12-24 VDC
Rectifier
100/115/
220/230 VAC
1ø, 50-60 Hz
100-230 VAC
Sensors
(IEC61162-450 Ed.1 format)
100-230 VAC
Sensors
(IEC61162-450 Ed.2 format)
VDR
(IEC61162-450 format)
100-230 VAC
100-230 VAC 1ø, 50-60 Hz
440 VAC 1ø, 50-60 Hz
24 VDC
100/115/220/230 VAC
1ø, 50-60 Hz
NOTICE
7
XN12CF-RSB128-123
XN20CF-RSB128-123
XN24CF-RSB128-123
Sub monitor
Control Unit
RCU-014 or RCU-015
3
Monitor Unit*
MU-190/MU-231/MU-270W
or
3
Monitor Unit*
MU-190HD
*11
/MU-192HD
Intelligent Hub
5
HUB-3000*
Switching Hub
HUB-100
OR
Intelligent Hub
6
HUB-3000*
VDR (Analog RGB)
Transformer
Rectifier PR-850A
)
Antenna Unit
Antenna
Cable*
10
Processor
Unit
RPU-025
For AC
power
For DC
power
for FAR-2218(-BB)/2318, 12 kW
(w/ Performance Monitor PM-32A
XN12CF-RSB128-105
XN20CF-RSB128-105
XN24CF-RSB128-105
for FAR-2228(-BB)/2328, 25 kW
(w/ Performance Monitor PM-32A
XN12CF-RSB128-106
XN20CF-RSB128-106
XN24CF-RSB128-106
: Standard supply
: Optional or local supply
USB Mouse
9
USB Device*
1
Gyrocompass*
(AD-10 format)
1
Gyrocompass*
(IEC61162 format)
AIS Transponder
2
EPFS*
(GPS)
SDME (Speed log)
AMS (IEC61162 format)
ECDIS
4
AMS (Contact)*
8
Sub monitor 1 of ECDIS*
8
Sub monitor 2 of ECDIS*
*7
)
*7
)
xvii

Advertisement

Table of Contents
loading