VIP X1 | Installation and Operating Manual
Malfunction
The unit does not
report an alarm.
Control of cameras
or other units is not
possible.
The unit is not opera-
tional after a firm-
ware upload.
iSCSI connections malfunctions
Malfunction
No LUNs are dis-
played after connec-
tion to the iSCSI
server.
„LUN FAIL" is dis-
played below a node
after connection to
the iSCSI server.
LUN mapping is not
possible.
Bosch Security Systems | 2006-12 | V2.5
Possible causes
Alarm source is not selected. Select possible alarm sources on
No alarm response speci-
fied.
The cable connection
between the serial interface
and the connected unit is not
correct.
The interface parameters do
not match those of the other
unit connected.
Power failure during pro-
gramming by firmware file.
Incorrect firmware file.
Possible causes
Incorrect LUN mapping dur-
ing iSCSI server configura-
tion.
The LUN map was not read-
able as it was assigned to
the wrong network interface.
Some iSCSI systems don't
support initiator extensions.
Solution
the Alarm sources configuration
page.
Specify the desired alarm response
on the Alarm connections config-
uration page, change the
IP address if necessary.
Check all cable connections and
ensure all plugs are properly fitted.
Make sure that the settings of all
units involved are compatible.
Have the unit checked by Cus-
tomer Service and replace if nec-
essary.
Enter the IP address of the unit fol-
lowed by /main.htm in your Web
browser and repeat the upload.
Solution
Check the iSCSI server configura-
tion and reconnect.
Check the iSCSI server configura-
tion and reconnect.
Delete the initiator extension on the
iSCSI settings configuration page.
EN | 125
Appendix