Bosch VIP X1 Installation And Operating Manual page 75

Operation manual
Table of Contents

Advertisement

VIP X1 | Installation and Operating Manual
Min. object size: (MOTION+ only)
You can specify the number of sensor fields that a moving object must cover to
generate an alarm. This setting prevents objects that are too small from trigger-
ing an alarm.
A minimum value of 4 is recommended. This value corresponds to four sensor
fields.
Global change %: (MOTION+ only)
You can define the percentage of sensor fields that must register a change
simultaneously before generating an alarm. This setting is independent of the
sensor fields selected under Select area.
This option allows you to detect, independently of motion alarms, manipulation
of the orientation or location of a camera resulting from turning the camera
mounting bracket, for instance.
Selecting the area (MOTION+ only)
The areas of the image to be monitored by the motion detector can be selected.
The video image is subdivided into 858 square sensor fields. You can activate
or deactivate each of these fields individually. If you wish to exclude particular
regions of the camera's field of view from monitoring due to continuous move-
ment (by a tree in the wind, etc.), the relevant fields can be deactivated.
– Click Select area to configure the sensor fields. A new window will open.
– If necessary, click Clear all first to clear the current selection (fields marked
red).
– Left-click the fields to be activated. Activated fields are marked red.
– If necessary, click Select all to select the entire video frame for monitoring.
– Right-click any fields you wish to deactivate.
– Click OK to save the configuration.
– Click the close button (X) in the window title bar to close the window without
saving the changes.