Appendix D: Card level status fields
Appendix D describes the meaning of different fields for the Card level of
the enhanced network (ENET). The following table lists the possible states
that can apply to the card sublevel.
Table
Slot status field values
Field value
—
O
I
S
C
M
T
14-1xxx
Meaning
OK. The card is in service (InSv).
Unequipped. The card is not equipped.
Offline. The card is offline (OFFL) as a result of manual
action.
In-service trouble (ISTb). A fault is present on the card.
The card remains InSv.
System busy (SysB). The system removed the card from
service.
Central side (C-side) busy. The card is out of service
(OOS) because the C-side links to the DMS-bus component
are OOS.
Manual busy (ManB). You manually removed the card from
service.
Test in progress. A maintenance action is now in progress
on the card.
DMS-100 Family Networks Maintenance Guide BASE10