Configuring Server Node 2 - Compaq 124708-001 - ProLiant Cluster - 1850 Software User's Manual

Compaq proliant cl1850 software user guide
Hide thumbs Also See for 124708-001 - ProLiant Cluster - 1850:
Table of Contents

Advertisement

12. Start the CR3500 Configuration Utility found in the Compaq System
Tools Folder. This utility allows you to configure the shared storage
RAID controllers and set up the logical drives. See Chapter 3, "CR3500
Configuration Utility," for detailed information on this utility.
NOTE: When using the CR3500 Configuration Utility, it is only necessary to configure the
shared drives during server node 1 setup. When configuring server node 2, the utility
shows the results of the shared drives configured during server node 1 setup.
13. After the shared storage drives have been configured, run the
Windows NT Disk Administrator to create volumes out of the logical
drives. Be sure to assign drive letters and format the volumes for NTFS.
14. Close Disk Administrator and restart Windows NT.
15. At the Enterprise Edition Installer, install Microsoft Cluster Server
Administrator (MSCS.) Refer to MSCS documentation for installation
steps.
16. After installing MSCS install the latest Service Pack if applicable.
17. To ensure latest Compaq drivers have not been overwritten by the
service pack, rerun the Server Support Software.

Configuring Server Node 2

1. Press Print Screen to access the KVM (Keyboard/Video/Mouse)
switch and choose server node 2 from the list.
NOTE: For detailed instructions on using the KVM switch, refer to the Compaq
ProLiant CL1850 User Guide.
2. Boot server node 2 with the SmartStart CD in the CD-ROM drive.
3. When the system boots, you will see the Select Language screen. Select
which language you would like to use and follow the installation
process.
4. When prompted to select an installation path select the Manual
Configuration path. Follow the guided installation process. If you need
help, refer to the online help by clicking on the Help button.
After the operating system has been selected, SmartStart runs the
System Configuration Utility and configures the server node's hardware.
It is very important that the adapter card in each server node connected
to the shared storage RAID controller have a unique SCSI ID number.
System Setup and Configuration for Microsoft Windows NT S/E 4.0 1-7