cpqHoTrapFlags
Supporting SNMP Trap Description: "Remote Insight keyboard cable disconnected."
NT Event ID: 1114 (Hex)0x8435045a (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A processor has crossed the threshold of allowable corrected errors. The processor
should be replaced.
SNMP Trap: cpqSeCpuThresholdPassed - 1001 in CPQSTDEQ.MIB
Symptom: This trap is sent when an internal processor error threshold has been passed on a particular
processor, causing it to become degraded. This trap is sent when cpqSeCpuThreshPassed transitions
from false to true.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSeCpuSlot
cpqSeCpuSocketNumber
Supporting SNMP Trap Description: "CPU internal corrected errors have passed a set threshold."
NT Event ID: 1115 (Hex)0x8435045b (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A computer cover has been removed since last system start up. Be sure the system
cover is installed properly. This situation may result in improper cooling of the system due to air flow
changes caused by the missing cover.
SNMP Trap: cpqSiHoodRemoved - 2001 in CPQSINFO.MIB
Symptom: The access panel is removed. The access panel status has been set to removed. The access
panel is not installed properly. This situation may result in improper cooling of the system due to air
flow changes caused by the missing access panel.
User Action: Replace the access panel and be sure that it is installed properly. Verify that the system is
working properly.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: "Hood is removed from unit."
NT Event ID: 1116 (Hex)0x8435045c (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the mouse cable is disconnected.
SNMP Trap: cpqSm2MouseCableDisconnected - 9009 in CPQSM2.MIB
Symptom: Mouse Cable Disconnected. The Remote Insight mouse cable has been disconnected.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags