Symptom: This trap is sent any time a physical adapter in a logical adapter group changes to the
Failed condition, but at least one physical adapter remains in the OK condition. This can be caused
by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter,
Hub, or Switch failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found,
the adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqNicIfPhysAdapterSlot
•
cpqNicIfPhysAdapterPort
•
cpqSiServerSystemId
•
cpqNicIfPhysAdapterStatus
•
cpqSePciSlotBoardName
•
cpqNicIfPhysAdapterPartNumber
•
ipAdEntAddr
•
cpqNicIfLogMapIPV6Address
•
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: "Redundancy decreased by adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]."
NIC agents 138