cpqHeResMem2BoardRiserNum
Supporting SNMP Trap Description: "Memory Board or Cartridge Inserted into Slot
[cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum],
Riser[cpqHeResMem2BoardRiserNum]."
NT Event ID: 1039 (Hex) 0x8435040FL (cpqsvmsg.dll)
Log Severity: Warning (3)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The
LockStep recovery engine has been activated. For instruction on replacing the faulty memory, see the
server documentation.
SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.MIB
Symptom: Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory
Protection subsystem has detected a memory fault. The LockStep engine has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
sysName,
cpqHoTrapFlags
Supporting SNMP Trap Description: "The Advanced Memory Protection subsystem has engaged the
LockStep memory."
NT Event ID: 1072 (Hex)0x84350430 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The frequency of memory errors is high enough such that tracking of correctable
memory errors has been temporarily disabled.
SNMP Trap: cpqHe3CorrectableMemoryLogDisabled - 6016 in CPQHLTH.MIB
Symptom: Correctable memory error tracking disabled. The frequency of errors is so high that the
error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated
the current tracking status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeCorrMemLogStatus
Supporting SNMP Trap Description: "Too many memory errors - tracking now disabled."
NT Event ID: 1082 (Hex)0xc435043a (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: A Thermal Temperature Condition has been set to failed. The system will be shut down
due to this thermal condition.
SNMP Trap: cpqHe3ThermalTempFailed - 6017 in CPQHLTH.MIB
Symptom: The temperature status has been set to failed. The system is shut down due to this thermal
condition.
Supporting SNMP Trap Data:
sysName
Server agents 89