Symptom: Tape Drive Cleaning Tape Needs Replacing. The Insight Agent has detected that an
autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced
with a new cleaning tape.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapePhyDrvCondition
Supporting SNMP Trap Description: "Status is now [cpqTapePhyDrvCondition]."
NT Event ID: 1121 (Hex)0x84350461 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: IDE Drive Status Degraded.
Log Message: The IDE drive %4 has a degraded status and should be scheduled for replacement.
SNMP Trap: cpqIdeDriveDegraded - 14001 in CPQIDE.MIB
Symptom: An IDE drive status has been set to degraded.
User Action: The drive should be scheduled for replacement. For detailed information on a component
replacement, see the appropriate Maintenance and Service Guide.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqIdeIdentIndex
Supporting SNMP Trap Description: "IDE drive [cpqIdeIdentIndex] has become degraded."
NT Event ID: 1122 (Hex)0x44350462 (cpqstmsg.dll)
Log Severity: Information (1)
Event Title: IDE Drive Status OK.
Log Message: The IDE drive %4 has returned to a normal operating condition.
SNMP Trap: cpqIdeDriveOk - 14002 in CPQIDE.MIB
Symptom: An IDE drive status has been set to OK.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqIdeIdentIndex
Supporting SNMP Trap Description: "IDE drive [cpqIdeIdentIndex] has returned to normal operating