HP 108164-003 - ProLiant - 800 Reference Manual page 136

Microsoft windows event id and snmp traps reference guide for use with smartstart version 8.25
Table of Contents

Advertisement

cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: "Redundancy decreased by adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]."
NT Event ID: 1290 (Hex)0x4435050A (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Connectivity has been restored for the NIC in slot %1, port %2.
SNMP Trap: cpqNic3ConnectivityRestored - 18011 in CPQNIC.MIB
Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the
physical adapter in a single adapter configuration returns to the OK condition or at least one physical
adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of
a faulty cable or re-attaching a cable that was unplugged.
User Action: None required.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
Supporting SNMP Trap Description: "Connectivity is restored for adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]."
NT Event ID: 1291 (Hex)0xc435050B (cpqnimsg.dll)
Log Severity: Error (3)
Log Message: Connectivity has been lost for the NIC in slot %1, port %2.
SNMP Trap: cpqNic3ConnectivityLost - 18012 in CPQNIC.MIB
Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition.
This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a
redundant configuration fails. This can be caused by loss of link due to a cable being removed from
the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this
condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found,
the adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
sysName
NIC agents 136

Advertisement