Be sure your air conditioner does not fall out of the opening
during installation or removal.
The place where the power cord exits the air conditioner
should be no more than 4 ft (122 cm) from a grounded outlet.
Be sure the wall where the air conditioner will be installed will
support the weight of the air conditioner.
Do not install the air conditioner where the plastic cabinet
front will be exposed to a heat source that raises the surface
temperature above 120ºF (49ºC).
Do not block the louvers in the front panel.
Wall sleeve dimensions: 26.75" x 15.75" x 15" (68 cm x
40 cm x 38.1 cm)
1. Remove the front and back covers from the new wall sleeve.
NOTE: Save the covers for future use to seal the wall sleeve if
the air conditioner is removed.
2. Clean out any debris from the inside of the wall sleeve,
making sure the inside is clean and that the drain holes are
completely open.
3. Insert new grille into sleeve.
NOTE: Make sure that the word "Top" is readable from inside
the room.
4. Secure the grille to the sleeve by inserting the 6 - #8 - 32 self-
tapping screws (provided) through the holes in the grille and
into the sleeve.

Complete Installation

1. Assemble trim frame by laying the 4 frame pieces face down
on a flat surface and snapping them securely together.
2. Install the
" insulating foam around the inside edge of the
trim frame. Begin in the bottom left corner and place the
insulating foam around the entire inside of trim frame. Check
to be sure foam is flush with the bottom edge of the trim
frame.
B
A. Insulating foam seals
B. Trim frame
3. Slide the trim frame onto the air conditioner until the foam
makes a seal with the wall sleeve.
A. Trim frame against wall sleeve
4. Check that Fan Control is Off.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
5. Plug into a grounded 3 prong outlet.
6. Press RESET on power supply cord.
A
B