  • Page 3: Technical Specification

    TECHNICAL SPECIFICATION Model RH-4773 Type 190F Displacement 420CC Rated Power 16HP Ignition System T.C.I Engine Start Type Hand Start/Electric starting Fuel Tank Capacity Continuous Working Fuel Type gasoline Type Open frame inverter generator Rated Voltage 230V Frequency 50Hz Generator Winding Material...
  • Page 4: Part List

    PART LIST Frame Fuel Tank Control Panel Air Filter Oil gauge Rubber Bottom Fuel Tank Cap Fuel level indicator Inverter Power Cylinder Head Muffler Starting Puller This operator's manual includes all relevant information, please read it carefully. operator's manual includes all relevant information, please read it carefully.
  • Page 5: User Responsibility

    YOU WILL FIND IMPORTANT SECURITY INFORMATION IN MANY FORMS, INCLUDING: 1- Safety label-pasted on the generator set. 2- The significance of these three warning words: DANGEROUS: If not follow these notices, it will be a risk of personal injury or death. CAUTIOUS: If not follow these notices, you will be injured.
  • Page 6: Electric Shock Hazard

    8- The angle of inclination cannot exceed 20 degrees from the horizontal plane, otherwise it may cause fuel spillage. 9- Don't place anything on the generator set to prevent a fire disaster. CARBON MONOXIDE POISONING HAZARD The exhaust gas from the generator set contains poisonous colorless and odorless carbon monoxide gas.
  • Page 7: Digital Display

    ignite some materials. 2- Place the generator set at least 1 meter away from buildings, or other equipment during operation. 3- Don't seal the generator set. 4- Please keep flammable and explosive materials away from the generator set. 5- The muffler will be very hot during operation and remain hot for some time after shootdown.
  • Page 8: Parallel Interface

    INDICATOR LIGHT GREEN: The running indicator light represents the normal operation of the equipment and the output voltage is Nirmal. RED: overload indicator light. BLINKING It means that the load of the generator set is too large, exceeding the rated power, and it is recommended to reduce the load power. YELLOW: engine oil indicator light, which means the amount of engine oil is low, please add engine oil in time, otherwise the generator set can’t run normally.
  • Page 9: Overload Protection

    OVERLOAD PROTECTION When the load is greater than 7.0kW, the red-light flashes. The load is protected within 30 seconds to close the output, and the red light is always on. SHORT CIRCUIT PROTECTION When the load is short-circuited, the product will be protected immediately, the output will be cutoff, the red light will always be on, and the power will be restored.
  • Page 10 Fuel Display Table Fuel Tank Cap Empty full Read and understand this operator's manual. Master the functions and operating of the control panel. When the generator set is used for power equipment, be careful not to exceed the load limit of the generator set. IS THE GENERATOR READY? For your safety and to maximize the life of your equipment, it is important to take some time to inspect the condition of your generator set before...
  • Page 11: Checking The Engine

    CHECKING THE ENGINE Check the oil level A low oil level will cause the oil warning system to stop the engine from running. Check the air filter. A dirty air filter will block air from entering the carburetor, reducing engine and generator performance. Check fuel level.
  • Page 12: Start The Generator Set

    START THE GENERATOR SET To prevent fire effectively, please keep at least 1 meter away from walls or other equipment during operation. Don’t place flammable and explosive items near the generator When running the generator set, keep a distance of more than 1 meter from walls or obstacles that may damage or cause the generator set to overheat.
  • Page 13 Damper USE ELECTRIC START position and keep it in that position until the engine start. If the engine fails to start within 5 seconds, release the switch, wait for more than 10 seconds, and then start the second time. NOTICE: The generator set shouldn’t start for more than 5 seconds each time, otherwise, the electric starter motor may overheat, or even damage the starter motor.
  • Page 14: Emergency Handling

    3- If the throttle handle is in the "OFF" position when the engine is started after the engine warms up, slowly put the throttle handle in the "Open" position. 1- Press the air switch to the “off” position. 2- Press the unit switch to the “off” position. 3- Turn the fuel valve to the “off”...
  • Page 15: Grounding System

    When the operation of electrical equipment becomes abnormal, such as a slow response or sudden stop, please stop immediately. Remove the connection between the electrical equipment and the generator set, and check whether it is a problem with the electrical equipment or because it exceeds the rated output of the generator set.
  • Page 16: The Importance Of Maintenance

    Remember that the dealer knows the performance of the generator set very well and has the complete equipment to maintain and repair it. To make sure the best quality and reliability, use new genuine RONIX parts or their equivalent for repair and replacement work.
  • Page 17: Maintenance Schedule

    repair. This will help eliminate some potential dangers. Carbon monoxide poisoning of engine exhaust. When operating the engine group at any time, make sure that the ventilation state is well. Burning parts cause burns let the engine and exhaust system be allowed before contact.
  • Page 18 Check to × adjust Spark plug × Replace Check to × Valve gap adjust Burning Clean Every 500 hours room Fuel tank × Clean and filter Fuel tank Every 2 years (if necessary, please × × Check pipe replace) Use in dusty areas, the maintenance frequency should be increased. These tasks should be carried out by dealers unless you have suitable tools and good technology.
  • Page 19: Engine Oil Level Inspection

    engine just stops, let it cool first. Try not to let the fuel overflow when refueling. The amount of refueling shouldn't exceed the fuel filter’s upper limit oil level. Tighten the fuel tank cover after refueling. Don't refuel the generator indoors, gasoline and gas may be exposed to flames and sparks causing a fire.
  • Page 20 Oil Plug Gauge Oil gauge Oil level upper When the oil level is lower than the minimum safety limit, the oil alarm system will automatically stop the engine. To avoid the inconvenience caused by accidents, please check the oil level regularly. ELECTRIC ENGINE OIL REPLACEMENT When the machine is heating, the oil is leaked by the oil to ensure fast, and it is completely exhausted to exhaust the oil.
  • Page 21: Air Filter Maintenance

    4- Tighten the oil plug ruler. After processing the used oil that has been used, wash your hands with soap and water. Sealing Ring Oil Level Upper Limit Oil gauge Oil plug ELECTRIC ENGINE OIL RECOMMENDATION The oil is a major factor affecting the performance and service life of the engine.
  • Page 22 5- Reinstall the air filter element into the air filter. 6- Reinstall the air filter cover and install the air filter bolts. Confirm that the air filter bolts are tightened so that there is no gap between the upper cover and the lower cover. Cover Air Filter Box Screw...
  • Page 23: Fuel Filter Cleaning

    Squeeze, Immerse don't tighten Squeeze don’t tighten 3- Wipe off the dust on the air filter seat and air filter cover with a damp cloth, and be careful not to let the dust enter the air pipe leading to the carburetor.
  • Page 24: Spark Plug Maintenance

    SPARK PLUG MAINTENANCE Spark plug recommendation: F7TC To ensure the normal operation of the generator set, the spark plug gap must be adjusted correctly and carbon deposits removed. electrode 0.7-0.8 mm Sealing ring NOTICE: Incorrect spark plugs can cause engine damage. If the engine is hot, maintain the spark plugs after it cools down.
  • Page 25 5- Make sure the spark plug seals are in good condition. To prevent the threads from slipping, carefully reinstall the spark plug by hand. 6- Afterreinstalling the spark plug, tighten it with the spark plug sleeve. If it is a used spark plug, tighten 1/8 -1/4 turn after the spark plug is tight. If it is a new spark plug, give it another 1/2 turn after the spark plug is tight.
  • Page 26: Storage Preparation

    Even in as little as 30 days, gasoline can deteriorate and oxidize and cause damage to the carburetor or fuel system. Please consult the RONIX power dealer for the local storage method.
  • Page 27: Engine Oil

    NOTICE: Gasoline is highly flammable and explosive. You could be burned or seriously injured while handling fuel. Fuel should only be handled outdoors. Wipe up spilled fuel promptly. 1- Check whether the fuel valve is closed. 2- Place a suitable gasoline container under the carburetor and use a funnel to prevent gasoline from spilling.
  • Page 28: Precautions For Storage

    5- Reinstall the spark plug. 6- Gently pull up the starter handle until resistance is felt. At this point, the piston is in the compression stroke and both the intake and exhaust valves are closed. Storing the engine in this state can help prevent internal corrosion.
  • Page 29: Troubleshooting

    If the cylinder was stored with oil on it, the engine may smoke slightly when restarted, this is normal If the generator set has been run before transport, allow the generator to cool for at least 15 minutes before loading the generator set on the transport vehicle.
  • Page 30 Wet spark plugs with fuel (flooded Dry the spark plugs and reinstall them engine Fuel filter failure; carburetor failure; Take the generator set to the RONIX ignition Power dealer or refer to the service failure; fuel valve blockage, etc. manual...
  • Page 31 Spoiled gasoline was added to the oil Fuel filter failure; carburetor failure; Take the generator set to a RONIX Power ignition dealer or refer to the service manual. failure; fuel valve blockage, etc. 3- VOLTAGE LINE SOCKET...