Download Print this page

ADLINK Technology cPCI-A3H20 User Manual

3u compactpci serial storage carrier blade

Advertisement

Quick Links

cPCI-A3H20
3U CompactPCI® Serial
Storage Carrier Blade
User's Manual
Manual Rev.:
Revision Date:
Part Number:
Leading EDGE COMPUTING
0.4 Preliminary
January 5, 2023
50M-00105-1000

Advertisement

loading
Need help?

Need help?

Do you have a question about the cPCI-A3H20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADLINK Technology cPCI-A3H20

  • Page 1 3U CompactPCI® Serial Storage Carrier Blade User’s Manual Manual Rev.: 0.4 Preliminary Revision Date: January 5, 2023 Part Number: 50M-00105-1000 Leading EDGE COMPUTING...
  • Page 2: Revision History

    Leading EDGE COMPUTING Revision History Revision Release Date Description of Change(s) 2022-12-12 Preliminary release 2022-12-16 Add installation info; clarifications 2022-12-23 Spec corrections/updates Spec updates 2023-01-05 Revision History...
  • Page 3: Preface

    Preface Copyright © 2022 ADLINK Technology, Inc. This document contains proprietary information protected by copy- right. All rights are reserved. No part of this manual may be repro- duced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
  • Page 4 Leading EDGE COMPUTING California Proposition 65 Warning WARNING: This product can expose you to chemicals including acrylamide, arsenic, benzene, cadmium, Tris(1,3-dichloro-2-propyl)phosphate (TDCPP), 1,4-Diox- ane, formaldehyde, lead, DEHP, styrene, DINP, BBP, PVC, and vinyl materials, which are known to the State of California to cause cancer, and acrylamide, benzene, cadmium, lead, mercury, phthalates, toluene, DEHP, DIDP, DnHP, DBP, BBP, PVC, and vinyl materials, which are known to the State of California to cause...
  • Page 5: Table Of Contents

    1 Introduction ................ 1 Overview................1 Features................1 Contents ................2 2 Specifications ..............3 cPCI-A3H20 Storage Carrier Blade Specifications....3 Block Diagrams..............5 I/O Connectivity Table ............6 3 Board Interfaces ..............7 cPCI-A3H20 Board Layout ..........7 cPCI-A3H20/P Assembly Layout ......... 8 cPCI-A3H20/M Assembly Layout ........
  • Page 6 Leading EDGE COMPUTING This page intentionally left blank. Table of Contents...
  • Page 7: List Of Figures

    Figure 3-1: cPCI-A3H20 Board Layout ..........7 Figure 3-2: cPCI-A3H20/P Assembly Layout ........8 Figure 3-3: cPCI-A3H20/M Assembly Layout ........8 Figure 3-4: cPCI-A3H20 Front Panel Layout ........9 Figure 3-5: CompactPCI Serial P1 Pin Definition Legend....16 List of Figures...
  • Page 8 Leading EDGE COMPUTING This page intentionally left blank. viii List of Figures...
  • Page 9: List Of Tables

    Storage Carrier Blade Specifications..3 Table 2-2: cPCI-A3H20 I/O Connectivity .......... 6 Table 3-1: cPCI-A3H20 Front Panel Status LED Descriptions ..9 Table 3-2: U.2 NVMe Pin Definition ..........10 Table 3-3: M.2 B-Key 2280 SATA Pin Definition ......12 Table 3-4: M.2 M-Key 2280 NVMe Pin Definition ......
  • Page 10 Leading EDGE COMPUTING This page intentionally left blank. List of Tables...
  • Page 11: Introduction

    Two configurations are available: the cPCI-A3H20/P storage carrier card blade is equipped with one 2.5" U.2 PCIe x4 slot and one M.2 2242/2280 PCIe x4 slot; the cPCI-A3H20/M stor- age carrier card blade is equipped with one M.2 2242/2280 PCIe x4 slot and 1x M.2 2242/2280 SATA slot.
  • Page 12: Contents

    Leading EDGE COMPUTING 1.3 Contents The cPCI-A3H20 is packaged with the following components. If any of the following items are missing or damaged, retain the ship- ping carton and packing material and contact the dealer for inspection. Please obtain authorization before returning any prod- uct to ADLINK.
  • Page 13: Specifications

    • 1x M.2 M-Key 2242/2280 NVMe PCIe x4 slot • 1x M.2 B-Key 2242/2280 SATA slot Status LEDs • Power status • LED 1: NVMe U.2 status (cPCI-A3H20/P only) • LED 2: NVMe M.2 status • LED 3: SATA M.2 status (cPCI-A3H20/M only) Power Input •...
  • Page 14 • Fire: Compliant to EN45545-2:2013+A1:2015 (HL 1-3) EL9 for PCB (R24 / R25) • Rolling Stock: BS EN 50155:2021 • CE LVD: Meets this requirement when installed in a CE LVD compliant chassis Table 2-1: cPCI-A3H20 Storage Carrier Blade Specifications Specifications...
  • Page 15: Block Diagrams

    Storage Carrier Blade cPCI-A3H20/P Connector PCIe x4 PCIe 3.0 Switch PCIe x4 M.2 NVME Key-M socket PCIe x4 2242/2280 M.2 SATA SATA Key-B socket SATA Redriver 2242/2280 cPCI-A3H20/M Power Power Supply CompactPCI Serial Figure 2-1: cPCI-A3H20 Functional Block Diagram Specifications...
  • Page 16: I/O Connectivity Table

    Leading EDGE COMPUTING 2.3 I/O Connectivity Table cPCI-A3H20/P cPCI-A3H20/M Function Faceplate Onboard Faceplate Onboard U.2 PCIe M.2 PCIe M.2 SATA Power Power Status LEDs U.2 NVMe M.2 SATA M.2 NVMe M.2 NVMe Table 2-2: cPCI-A3H20 I/O Connectivity Specifications...
  • Page 17: Board Interfaces

    Board Interfaces 3.1 cPCI-A3H20 Board Layout CompactPCI Serial P1 connectors U.2 NVMe connector M.2 B-Key 2280 SATA connector M.2 M-Key 2280 NVMe connector (PCIe mode only) Figure 3-1: cPCI-A3H20 Board Layout Board Interfaces...
  • Page 18: Cpci-A3H20/P Assembly Layout

    Leading EDGE COMPUTING 3.2 cPCI-A3H20/P Assembly Layout M-Key Figure 3-2: cPCI-A3H20/P Assembly Layout 3.3 cPCI-A3H20/M Assembly Layout M-Key B-Key Figure 3-3: cPCI-A3H20/M Assembly Layout Board Interfaces...
  • Page 19: Cpci-A3H20 Front Panel

    No power Power good U.2 NVMe Blinking Transmitting (cPCI-A3H20/P only) Not working Power good M.2 NVMe Blinking Transmitting Not working Power good M.2 SATA Blinking Transmitting (cPCI-A3H20/M only) Not working Table 3-1: cPCI-A3H20 Front Panel Status LED Descriptions Board Interfaces...
  • Page 20: Connector Pin Assignments

    Leading EDGE COMPUTING 3.5 Connector Pin Assignments U.2 NVMe (CN1) Signal Name Signal Name U2_PCIE_CLK0_P U2_PCIE_CLK0_N U2_PCIE_TX0_P U2_PCIE_TX0_N U2_PCIE_RX0_N U2_PCIE_RX0_P P_+3V3_A PLTRST_U2_KEY_N U2_WAKE_N sPCIeRst ClkReq# FDET_N U2_PCIE_TX1_P U2_PCIE_TX1_N U2_PRSNT_N U2_PCIE_RX1_N Table 3-2: U.2 NVMe Pin Definition Board Interfaces...
  • Page 21 Signal Name Signal Name LED_U2_ACT# U2_PCIE_RX1_P P_+12V_A U2_PCIE_TX2_P Table 3-2: U.2 NVMe Pin Definition Board Interfaces...
  • Page 22: Table 3-3: M.2 B-Key 2280 Sata Pin Definition

    Leading EDGE COMPUTING M.2 Socket B-Key 2280 SATA (CN2) Signal Name Signal Name P_+3V3_A P_+3V3_A TP10 P1_USB2_P TP11 P1_USB2_N LED_M2_KEYB_ACT# B-Key M2_1_DPR Reserved for USB Reserved for USB Reserved for USB Reserved for USB P1_SATA_M2_TX_P P1_SATA_M2_TX_N P1_SATA_M2_RX_N P1_SATA_M2_RX_P PLTRST_M2_KEY-B_N M2_KEY-B_CLKREQ_N M2_KEY-B_WAKE_N Table 3-3: M.2 B-Key 2280 SATA Pin Definition Board Interfaces...
  • Page 23 Signal Name Signal Name PLTRST_M2_KEY-B_N P_+3V3_A P_+3V3_A P_+3V3_A Table 3-3: M.2 B-Key 2280 SATA Pin Definition Pins 29, 31, 35 and 37 are reserved for USB. Please contact your ADLINK representative for more information. NOTE: NOTE: Board Interfaces...
  • Page 24: Table 3-4: M.2 M-Key 2280 Nvme Pin Definition

    Leading EDGE COMPUTING M.2 Socket M-Key 2280 NVMe (CN3) Signal Name Signal Name P_+3V3_A P_+3V3_A M2_PCIE_RX3_P M2_PCIE_RX3_N LED_M2_KEYM_ACT# M2_PCIE_TX3_P P_+3V3_A M2_PCIE_TX3_N P_+3V3_A P_+3V3_A M2_PCIE_RX2_P P_+3V3_A M2_PCIE_RX2_N M2_PCIE_TX2_P M2_PCIE_TX2_N M2_PCIE_RX1_P M2_PCIE_RX1_N M2_PCIE_TX1_P M2_PCIE_TX1_N M2_1_DEVSLP M2_PCIE_RX0_P M2_PCIE_RX0_N M2_PCIE_TX0_P M2_PCIE_TX0_N PLTRST_M2_KEY-M_N M2_KEY-M_CLK_REQ_N Table 3-4: M.2 M-Key 2280 NVMe Pin Definition Board Interfaces...
  • Page 25 Signal Name Signal Name M2_PCIE_CLK0_N M2_KEY-M_PEWAKE_N M2_PCIE_CLK0_P M-Key M2_1_SUSCLK P_+3V3_A P_+3V3_A P_+3V3_A P_+3V3_A Table 3-4: M.2 M-Key 2280 NVMe Pin Definition Board Interfaces...
  • Page 26: Figure 3-5: Compactpci Serial P1 Pin Definition Legend

    Leading EDGE COMPUTING CompactPCI Serial P1 Connector 1_PE_R 1_PE_ 1_PE_TX 1_PE_ 1_PE_ 1_PE_ 1_PE_ 1_PE_ X03- RX03+ TX03+ RX02- RX02+ TX02- TX02+ 1_PE_ 1_PE_ 1_PE_ 1_PE_ 1_PE_ 1_PE_ 1_PE_ 1_PE_ RX01- RX01+ TX01- TX01+ RX00- RX00+ TX00- TX00+ 1_SATA 1_SAT 1_SATA_ 1_SATA PE_CL...
  • Page 27: Getting Started

    Getting Started This chapter describes the following installation procedures for the cPCI-A3H20 carrier blade:  2.5" U.2 NVMe drive (cPCI-A3H20/P only)  M.2 M-Key NVMe module  M.2 B-Key SATA module (cPCI-A3H20/M only) Getting Started...
  • Page 28: Cpci-A3H20/P

    4.1 cPCI-A3H20/P 2.5" U.2 NVMe Drive Installation The cPCI-A3H20/P provides space to install a 2.5" U.2 NVMe drive. Install the drive to the bracket by inserting it into the U.2 connector and fastening the four screws provided as shown below.
  • Page 29 M.2 M-Key NVMe Module Installation The cPCI-A3H20/P provides space to install an M.2 NVMe mod- ule. Install the module by inserting it into the M.2 connector and fastening the screw provided as shown below. Getting Started...
  • Page 30: Cpci-A3H20/M

    4.2 cPCI-A3H20/M M.2 B-Key SATA and M-Key NVMe Module Installation The cPCI-A3H20/M provides space to install an M.2 B-Key SATA and M.2 M-Key NVMe module. Install each module by inserting it into the corresponding M.2 connector and fastening the screw pro- vided as shown below.
  • Page 31: 2242 Modules

    4.3 M.2 2242 Modules To install M.2 2242 modules, remove the standoff from the default location (for M.2 2880 modules) and reinstall it in the location shown. Getting Started...
  • Page 32 Leading EDGE COMPUTING This page intentionally left blank. Getting Started...
  • Page 33: Important Safety Instructions

    Important Safety Instructions For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment.  Read these safety instructions carefully.  Keep this user’s manual for future reference.
  • Page 34 Leading EDGE COMPUTING  Never attempt to fix the equipment. Equipment should only be serviced by qualified personnel. A Lithium-type battery may be provided for uninterrupted, backup or emergency power. Risk of explosion if battery is replaced with one of an incorrect type.
  • Page 35: Getting Service

    San Jose, CA 95119-1208, USA Tel: +1-408-360-0200 Toll Free: +1-800-966-5200 (USA only) Fax: +1-408-600-1189 Email: info@adlinktech.com ADLINK Technology (China) Co., Ltd. 300 Fang Chun Rd., Zhangjiang Hi-Tech Park Pudong New Area, Shanghai, 201203 China Tel: +86-21-5132-8988 Fax: +86-21-5132-3588 Email: market@adlinktech.com...

This manual is also suitable for:

Cpci-a3h20/pCpci-a3h20/m