current for test need to be 3%F.S.
*10
When loopSpeed Low is low,it can better complied DUT's characteristics; When LoopSpeed is High,
the dynamic response time is faster.
*11
Test conditions: Test current >10% F.S., test frequency <150Hz.
*12
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the
range of phase Angle can be set.
*13
1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz.
*14
Test conditions: 380VLL/50Hz AC input, 350Vrms/50Hz/full power output.
All the above parameters are subject to change without prior notice from ITECH.
Copyright ©ITECH Electronic Co., Ltd.
Technical Specifications
167
Need help?
Do you have a question about the IT7900P Series and is the answer not in the manual?