Parameter
ID
U 15
Zone 3 cooling flow set point in case of no thermal regulation ("R 01" = OFF)
U 16
Zone 3 central heating offset
U 17
Zone 3 cooling offset
U 18
Zone 3 humidity setpoint
U 21
Hour setting (internal clock)
U 22
Minutes setting (internal clock)
U 23
Day of the week
U 24
Current day
U 25
Current month
U 26
Current year
U 32
Start time of the DHW recirculation function
U 33
End time of the DHW recirculation function
U 50
Venting
The parameters referring to zone 2 can only be displayed if there is a zone 2 on the system and it is configured correctly.
The parameters referring to zone 3 can only be displayed if there is a zone 3 on the system and it is configured correctly.
Description
In the case of new central heating systems and in
particular mode for floor systems, it is very impor-
tant that de-aeration is performed correctly. The
function consists of the cyclic activation of the
pump (100 s ON, 20 s OFF) and the 3-way valve (120
s D.H.W., 120 s heating system).
The function lasts for 18 hours and it is possible to
stop it by pressing "ESC" and setting the function
on "OFF". Activation of the function is signalled by
the countdown shown on the indicator (14).
ST.008706/000
Range
5 ÷ 25 °C
- 15 ÷ + 15 °C
- 15 ÷ + 15 °C
30 ÷ 70
0 - 23 hours
0 - 59 minutes
Mo-Tu-We-
Th- Fr-Sa-Su
1 ÷ 31
1 ÷ 12
00 ÷ 99
0 - 23 hours
0 - 23 hours
OFF - ON
Magis Combo 12/14/16 Plus V2 I
Customised
Default
value
20
0
0
50
OFF
91