Heat regulation menu.
Parameter
ID
R 01
External probe
Outdoor temperature for max
R 02
CH flow zone 1
Outdoor temperature for min
R 03
CH flow zone 1
Zone 1 maximum central
R 04
heating
Zone 1 minimum central
R 05
heating
Outdoor temperature for Zone 2
R 06
low temperature zone max. CH
flow
Outdoor temperature for Zone 2
R 07
low temperature zone min. CH
flow
Zone 2 low temperature zone
R 08
maximum central heating
Zone 2 low temperature zone
R 09
minimum central heating
Zone 1 outdoor temperature for
R 10
minimum cooling flow
Outdoor temperature for Zone 1
R 11
maximum cooling flow
R 12
Zone 1 minimum cooling
R 13
Zone 1 maximum cooling
118
Magis Combo 12/14/16 Plus V2 I
Description
Defines if and which external probe is used to
manage the system. OFF = no external probe is
used
OU = external probe on the Outdoor Unit
IU = optional external probe connected to the
Indoor Unit
Establishes the outdoor temperature at which to
have the maximum flow temperature of zone 1.
Establishes the outdoor temperature at which to
have the minimum flow temperature of zone 1.
Defines the maximum flow temperature in zone 1
room central heating mode
Defines the minimum flow temperature in zone 1
room central heating mode
Establishes the outdoor temperature at which to
have the maximum flow temperature of zone 2
Establishes the outdoor temperature at which to
have the minimum flow temperature of zone 2
Defines the maximum flow temperature in zone 2
room central heating mode
Defines the minimum flow temperature in zone 2
room central heating mode
Establishes the maximum outdoor temperature at
which to have the minimum flow temperature in
zone 1 cooling mode
Establishes the minimum outdoor temperature at
which to have the maximum flow temperature in
zone 1 cooling mode
Defines the minimum flow temperature in zone 1
room cooling mode
Defines the maximum flow temperature in zone 1
room cooling mode
ST.008706/000
Range
Default
OFF - OU - IU
OU
-15 ÷ 25 °C
-5
-15 ÷ 25 °C
25
20 ÷ 80
55
20 ÷ 80
25
-15 ÷ 25 °C
-5
-15 ÷ 25 °C
25
20 ÷ 80
40
20 ÷ 80
25
20 ÷ 40
35
20 ÷ 40
25
05 ÷ 20
7
05 ÷ 25
12
Customised
value