When the circulation within each room central heating loop is controlled by remotely operated valves, it is important to guar-
antee the minimum water content (50 litres), even if all the valves are closed.
When the circulation within each or certain room central heating loops is controlled by remotely operated valves, it is impor-
tant to guarantee the minimum flow rate, even if all the valves are closed. It is necessary to have a loop that is always open on the
system (by-pass or non-intercepted zone), to allow some functions such as, for example, the antifreeze function.
Failure to comply with the above implies personal responsibility and invalidates the
warranty.
1.3
DATA NAMEPLATE AND INSTALLATION INFORMATION STICKER
1.3.1
Data nameplate positioning
1
ST.008706/000
Magis Combo 12/14/16 Plus V2 I