Download Print this page

Immergas Magis Combo 12 Plus V2 I Instructions And Recommendations page 13

Advertisement

When the circulation within each room central heating loop is controlled by remotely operated valves, it is important to guar-
antee the minimum water content (50 litres), even if all the valves are closed.
When the circulation within each or certain room central heating loops is controlled by remotely operated valves, it is impor-
tant to guarantee the minimum flow rate, even if all the valves are closed. It is necessary to have a loop that is always open on the
system (by-pass or non-intercepted zone), to allow some functions such as, for example, the antifreeze function.
Failure to comply with the above implies personal responsibility and invalidates the
warranty.
1.3
DATA NAMEPLATE AND INSTALLATION INFORMATION STICKER
1.3.1
Data nameplate positioning
1
ST.008706/000
Magis Combo 12/14/16 Plus V2 I
Key (Fig. 2):
1
-
Data plate
2
13

Advertisement

loading
Need help?

Need help?

Do you have a question about the Magis Combo 12 Plus V2 I and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Magis combo 14 plus v2 iMagis combo 16 plus v2 iMagis combo 4 plus v2Magis combo 6 plus v2Magis combo 9 plus v2