1.25 CONCENTRIC HORIZONTAL KIT INSTALLATION
Type C configuration, sealed chamber and fan assisted
The position of the terminal (in terms of distances from openings, overlooking buildings, floor, etc.) must be in compliance with the reg-
ulations in force.
This terminal is connected directly to the outside of the building for air intake and flue gas exhaust.
The horizontal kit can be installed with the rear, right side, left side or front outlet.
For installation with frontal outlet, one must use the fixing plate and a concentric bend coupling in order to ensure sufficient space to
carry out the tests required by law upon commissioning.
External grid
Make sure that the external silicone wall sealing plate is properly inserted in the wall.
For correct functioning of the system the terminal with grid must be installed correctly ensuring that, the "high" indication
present on the terminal is respected on installation.
Horizontal intake/exhaust assembly kits Ø 60/100 (Fig. 29)
1. Install the curve with flange (2) on the central hole of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange, and tighten using the screws contained in the kit.
2. Fit the Ø 60/100 (3) concentric terminal pipe with the male side (smooth) to the female side of the bend (2) up to the end stop, making
sure that the internal and external wall sealing plates have been fitted; this will ensure sealing and joining of the elements making up
the kit.
2
1
3
Extensions for horizontal kit Ø 60/100 (L = Equivalent length - L max = Maximum length) (Fig. 30).
115
The maximum lengths ((L max) of the various flues that can be installed are given in the summary table in parag. 1.22.
44
Magis Combo 12/14/16 Plus V2 I
4
5
The kit includes (Fig. 29):
C
13
N°1 Gasket (1)
N°1 Concentric bend Ø 60/100 (2)
N°1 Int./exhaust concentric terminal Ø 60/100 (3)
N°1 Internal wall sealing plate (4)
N°1 External wall sealing plate (5)
29
L
L ≤ L max
ST.008706/000
C
13
225
30