User Menu.
Parameter
ID
U 01
Zone 2 heating flow set point in case of no thermal regulation ("R 01" = OFF).
U 02
Zone 2 cooling flow set point in case of no thermal regulation ("R 01" = OFF)
U 03
Zone 1 central heating offset
U 04
Zone 2 central heating offset
U 05
Zone 1 cooling offset
U 06
Zone 2 cooling offset
U 07
Zone 1 humidity setting
U 08
Zone 2 humidity setting
U 11
Night function
U 12
Night function enabling time
U 13
Night function disabling time
U 14
Zone 3 heating flow set point in case of no thermal regulation ("R 01" = OFF).
90
Magis Combo 12/14/16 Plus V2 I
Description
You can edit the flow temperature with respect to
the external probe regulation curve in central heat-
ing mode (Parag. 1.18, Offset value)
You can edit the flow temperature with respect to
the external probe regulation curve in cooling
stage (Parag. 1.18, Offset value)
The humidity temperature sensor (optional) de-
fines room humidity in the corresponding area
Activating the function allows you to reduce the
compressor frequency during the Outdoor Unit
operation in the time slot set in the U 12 and U 13
parameters.
Make sure the additional power sources needed to
meet potential requirements that may present
themselves during active operation are available.
ST.008706/000
Customised
Range
Default
20 ÷ 80°C
25
5 ÷ 25 °C
20
- 15 ÷ + 15 °C
0
- 15 ÷ + 15 °C
0
- 15 ÷ + 15 °C
0
- 15 ÷ + 15 °C
0
30 ÷ 70 %
50
30 ÷ 70 %
50
OFF - ON
OFF
0 ÷ 23
0
0 ÷ 23
0
20 ÷ 80 °C
25
value