Download Print this page

Immergas Magis Combo 12 Plus V2 I Instructions And Recommendations page 150

Advertisement

4.13 TABLE 2 REGULATION 813/2013 (MAGIS COMBO 14 PLUS V2 T I)
Model
Air/water heat pump
Water/water heat pump
Brine/water heat pump
The parameters are declared for average temperature application, except for low temperature heat pumps. The parameters for low temperature heat
pumps are declared for low temperature application
The parameters are declared for average climatic conditions
Element
Rated heat output (*)
Central heating capacity declared with a partial load and indoor
temperature equivalent to 20°C and outdoor temperature T
T
= – 7 °C
j
T
= + 2 °C
j
T
= + 7 °C
j
T
= + 12 °C
j
T
= bivalent temperature
j
T
= operating limit temperature
j
for air/water heat pumps:
T
= – 15 °C (se TOL < – 20 °C)
j
Bivalent temperature
Central heating capacity cycle intervals
Degradation coefficient (**)
Different mode of energy consumption from the active mode
OFF mode
Thermostat mode off
Standby mode
Guard heating mode
Other items
Capacity control
Indoor/outdoor sound level
Emissions of nitrogen oxide
For mixed central heating appliances with a heat pump
Stated load profile
Daily electrical power consumption
Contact information: Immergas S.p.A. via Cisa Ligure n.95
(*) For heat pump appliances for space heating and heat pump mixed heating appliances, the nominal heat output Pnominal is equal to the design
load for central heating Pdesignh and the nominal heat output of an additional heater Psup is equal to the additional central heating capacity
sup(Tj).
(**) If Cdh is not determined by a measurement, the degradation coefficient is Cdh = 0,9.
150
Magis Combo 12/14/16 Plus V2 I
MAGIS COMBO 14 PLUS V2 T I
YES
Low temperature heat pump
NO
With Supplementary heater
NO
Mixed central heating device with heat pump:
Symbol
Value
Unit
Room central heating seasonal energy
Prated
13
kW
efficiency
Performance coefficient declared or primary energy index for partial
load it, with indoor temperature equivalent to 20°C and outdoor
j
temperature T
Pdh
11,1
kW
T
Pdh
7,0
kW
T
Pdh
4,5
kW
T
Pdh
4,6
kW
T
Pdh
11,1
kW
T
Pdh
12,0
kW
T
for air/water heat pumps:
Pdh
-
kW
T
For air/water heat pumps: Operating limit
T
-7
°C
biv
temperature
Pcych
-
kW
Cycle intervals efficiency
Cdh
0,9
-
Water heating temperature operating limit
Additional heater
P
0,022
kW
Rated heat output (*)
OFF
P
0,022
kW
TO
P
0,022
kW
Type of energy supply voltage
SB
P
0,000
kW
CK
For air/water heat pumps: air flow rate to
variable
outside
L
53 / 58
dB
For water\water or brine\water heat pumps:
WA
nominal flow of brine or water, outdoor heat
mg\
NO
28
exchanger
X
kWh
-
Water central heating energy efficiency
Q
-
kWh Daily fuel consumption
elec
ST.008706/000
Element
j
= – 7 °C
j
= + 2 °C
j
= + 7 °C
j
= + 12 °C
j
= bivalent temperature
j
= operating limit temperature
j
= – 15 °C (se TOL < – 20 °C)
j
NO
YES
NO
Symbol
Value
Unit
η
136
%
s
COPd
2,14
-
COPd
3,27
-
COPd
4,72
-
COPd
6,39
-
COPd
2,14
-
COPd
1,90
-
COPd
-
-
TOL
-10
°C
COP-
-
-
cych
WTOL
55
°C
Psup
0,5
kW
gas
-
5940
m
\h
3
-
-
m
\h
3
η
-
%
wh
Q
-
kWh
fuel