4.2 COMBUSTION PARAMETERS
Indoor Unit data
Gas type
Supply pressure
Gas nozzle diameter
Ignition fan speed
Post ventilation fan speed
Flue flow rate at D.H.W. nominal heat output
Flue flow rate at heating nominal heat output
Flue flow rate at min heat output
CO
at Nominal Q.
2
*O
at Nominal Q.
2
CO
at Ignition Q.
2
*O
at Ignition Q.
2
CO
at Minimum Q.
2
*O
at Minimum Q.
2
CO with 0% O
at Nom./Min. Q.
2
NO
with 0% O
at Nom./Min. Q.
x
2
Flue temperature at nominal output
Flue temperature at minimum output
Max air combustion temperature
Maximum flue gas circuit temperature
* O
values refer to gas 20%H2NG
2
136
Magis Combo 12/14/16 Plus V2 I
mbar
mm
rpm
rpm
kg/h
kg/h
kg/h
9,4 (9,2 ÷ 9,6)
%
4,1 (4,4 ÷ 3,7)
9,4 (9,2 ÷ 9,6)
%
4,1 (4,4 ÷ 3,7)
8,6 (8,4 ÷ 8,8)
%
5,5 (5,9 ÷ 5,1)
ppm
mg/kWh
°C
°C
°C
°C
ST.008706/000
G20
G31
20,0
37,0
5,60
4,00
1900
1900
2500
2500
52
54
52
54
9
10
10,3 (10,1 ÷ 10,5)
5,2 (5,5 ÷ 4,9)
10,3 (10,1 ÷ 10,5)
5,2 (5,5 ÷ 4,9)
9,6 (9,4 ÷ 9,8)
- (- ÷ -)
165 / 1
182 / 3
64 / 15
45 / 22
80
77
68
62
50
50
120
120