Download Print this page

Click Codes - LOGICDATA COSMO SYDNEY Original Instructions Manual

Adjustable bed frame

Advertisement

Parts of the Bed Frame remain in
an elevated position after a power
failure.
NOTICE
When an Emergency Lowering is performed, only the Bed Frame connected to the Battery Strap will be operated.
You will need to perform separate Emergency Lowerings for Bed Frames connected by the Sync Cable.
Parts of the Bed Frame do not
move evenly.

CLICK CODES

As soon as the Bed Frame is connected to the power outlet, the Control Box uses installed relays (clicks) to
inform the user about system status and the reason for the last shutdown. Codes are only transmitted during
system startup. Potential click codes are as follows:
CODE
2 X Click
1 X Click
4-6 X Click
26 // COSMO SYDNEY ADJUSTABLE BED FRAME – ORIGINAL INSTRUCTIONS
If power cannot be restored, an Emergency Lowering is required. Proceed
as follows:
1. Unplug the Power Converter from the power outlet.
2. Disconnect the Power Converter from the Cable Leading to the Control Box.
3. Connect the Battery Strap to the Control Box Cable instead.
4. Connect two 9V batteries to the Battery Strap.
5. Use the Head DOWN/UP, Foot DOWN/UP or Sleeping Position Buttons to
drive the Bed Frame to its lowest position.
Once Emergency Lowering is complete and power is restored, you can
reconnect the Power Converter. Then, perform a Reference Drive (see Chapter
5) and operate the Bed Frame as normal.
Make sure no persons or heavy objects are on the Bed Frame or in the range
of moving parts.
The Bed Frames may be misaligned. Follow the instructions in the section
"Fixing Misalignment" to realign the Bed Frames.
DEFINITION
Normal operation. Continue to operate the Bed Frame.
The system is working in emergency operation mode. Contact Customer support.
An internal error has occured. Contact customer support.