1. The Citrix wizard will generate a page named default.htm that will cause a
failure in the version of Internet Explorer included with Winterm software
version 3.5. The generated page attempts to display a pop-up browser window.
The Internet Explorer version on the terminal does not support this capability
and the browser simply displays a blank page with a small red X in the upper left
corner. There are several ways to avoid this problem:
Instruct users to reference the explicit URL http://<servername>/login.htm
Remove the page named default.htm and rename the page named login.htm to
default.htm
Using the Internet Information Service (IIS) management facility, insert the page
named login.htm into the list of default pages and then promote it to the first
position in the list.
The individual site requirements will dictate which is the best choice.
2. An additional configuration requirement results from the fact that the Internet
Explorer version on the terminal does not support Microsoft's ActiveX. If the
server is configured to launch applications embedded within the browser
window, the terminal's attempt to access these applications will fail. The Web
site must be configured to launch applications in a separate window. This will
result in running the ICA client code resident on the terminal to create the
window for accessing the published application.