4) When the build-in sensor is on and cannot be adjusted ion balance to zero by pressing the button,
turn the sensor off.
· The sensor may malfunction if there is an object with too much charge around it.
5) Use specified brackets for fixing.
· If use a bracket other than specified bracket, the functions of this product may not operate normally.
Warning
1) Before wiring, ensure that the power supply capacity meets the specification and that the voltage is
within the specification. Product damage or malfunction can result.
2) To maintain product performance, the power supply should be UL Class 2 certified by National
Electric Code (NEC) or evaluated as a limited power source according to UL60950.
3) To maintain the product performance, ground the product with an earth ground cable with a
resistance of 100 Ω or less. If the product is not grounded, it is not possible to secure the
performance and may lead to product failure or malfunction.
4) Wiring (including insertion and removal of the power supply connector) should never be carried out
with the power supply ON. Otherwise, an electrical shock or accident may occur.
5) Use specified cable for connecting this product. Do not disassemble or retrofit them. Disassembling
or modifying the product may cause product, electric shock or fire. The product will not be
guaranteed if it is disassembled and/or modified.
6) Ensure the safety of wiring and surrounding conditions before supplying power.
7) Do not connect or disconnect the connectors (including power source) while the power is supplied.
Failure to follow this procedure may cause product malfunction.
8) If the power and high voltage cables are routed together, the product may malfunction due to noise.
Route the Ionizer wires separately.
9) Confirm that the wiring is correct before operation. Incorrect wiring will lead to product damage or
malfunction.
10) Flush the piping before connecting. Before piping this product, exercise caution to prevent
particles, water drops, or oil contents from entering the piping.
Warning
1) Operate the product in the specified ambient temperature range.
· Operating ambient temp. range: Ionizer 0 to 40
· Do not use the product in locations where the temperature may change suddenly even if the ambient
temperature range is within the specified limits, resulting in condensation.
· Large difference between the ambient temperature and the fluid temperature may cause condensation
inside the piping or the ionizer housing. If the temperature difference is large, use a temperature controller
or similar device to reduce the temperature difference.
2) Do not use this product in an enclosed space.
· This product utilizes the corona discharge phenomenon. Do not use the product in an enclosed space as
ozone and nitrogen oxides exist, even though in marginal quantities.
3) Environments to avoid
· Never use or store under the following conditions. These may cause an electric shock, fire, etc.
a. Use in the environment which ambient temperature is out of the product specification.
b. Use in the environment which ambient humidity is out of the product specification.
c. Environment where abrupt temperature changes may cause condensation.
d. Environment where corrosive gas, flammable gas or other volatile flammable substances are stored.
e. Environment where the product may be exposed to conductive powder such as iron powder or dust, oil
mist, salt, organic solvent, machining chips, particles or cutting oil (including water and any liquids), etc.
f. Paths of direct air flow, such as air conditioners.
g. Enclosed or poorly ventilated environment
h. Locations which are exposed to direct sunlight or heat radiation.
i. Areas where strong electromagnetic noise is generated, such as strong electrical and magnetic fields
or supply voltage spikes.
j. Environment where static electricity is generated to the product.
k. Locations where strong high frequency is generated.
Electrical connection / Piping
Operating / Storage Environment
o
C, Remote controller 0 to 45
7
C, AC adapter 0 to 40
o
o
C.
Need help?