5) Tighten the screws to the specified torque.
· If the screws are tightened in excess of the specified torque range, it may damage the mounting screws or
mounted areas.
· If the tightening torque is insufficient, the mounting screws and brackets may become loose.
6) Do not directly touch the emitters.
· Do not directly touch the emitter with your finger. If the needle sticks to your finger, or electrical shock
makes an instantaneous rapid body motion to escape from the shock, causing injury.
· If emitter or cartridge is damaged by tools, etc., it may interfere with the specified function and performance,
and may also cause operation failure and accident.
High voltage caution
The emitter carries high voltage. If
foreign matter is inserted or human
body touches the emitter, electrical
shock or instantaneous reaction of
body to escape.
from the shock, causing injury.
7) Do not affix any tape or labels to the product.
· If the tape or label contains any conductive adhesive or reflective paint, a dielectric phenomenon may occur
due to ions arising from such substances, resulting in electrostatic charging or electric leakage, causing
malfunction, breakage, electric shock or fire.
8) Be sure to remove power supply and air supply to the Ionizer before starting the product installation.
· If installation or adjustment is performed being supplied with power, electric shock, failure or injury can
result.
9) Do not damage the cable or apply a heavy object or pinch the cable. Avoid repeatedly bending or
stretching the cable.
· It may cause an electric shock, fire, or breaking of wire.
10) Do not carry this product by holding its cables.
· It may cause an injury or damage to the product.
11) This product may cause interference if used in residential premises.
Caution
1) When installing this product, provide the space shown in the figure below from a wall or structure.
· If there are electrically conductive objects such as walls or structures close to the ionizer, generated ions
may not reach the target object effectively or product failure or electric shock can result due to dielectric or
short-circuit.
2) After installation, verify the performance of this product.
· The performance of the product varies depending on the surrounding installation and operating conditions.
After installation, verify the performance of this product.
3) When installing Ionizers which operate in DC mode (one polarity, positive or negative) with IZS51
close together, they should be positioned at least two meters away from each other.
· When IZS51 which operates in AC close to the Ionizer
which operates in DC mode, separate them by at least
two meters. The offset voltage (ion balance) may not be
adjusted by the built-in sensor due to the ions discharged
from the Ionizer which operates in DC mode.
DC mode
6
AC mode
2m or more
unit:mm