Troubleshooting The Css 11800 Modules; Table 2-15 Troubleshooting The Css 11800 Modules - Cisco CSS-11051-AC Hardware Installation Manual

11000 series content services switch
Table of Contents

Advertisement

Chapter 2
Cabling the CSS
Note

Troubleshooting the CSS 11800 Modules

78-15146-02
Installing a second CSS 11800 power supply provides power load balancing
between the two power supplies. When you install a second power supply, it
powers on and begins to share the power load automatically.
Each CSS 11800 module is equipped with a temperature sensor that detects an
over- or under-temperature condition. If the module detects that its temperature is
out of range, it generates a log message.
Module status is indicated by the Status LED on the module front panel. For
information about the module LEDs, see the module information earlier in this
chapter.
Table 2-15 provides suggestions for correcting problems that may occur with the
modules.

Table 2-15 Troubleshooting the CSS 11800 Modules

Symptom
System cannot identify
module type.
System cannot find an image
for the module.
Module failed diagnostic
(according to the
information in the Boot.log
file).
Cisco 11000 Series Content Services Switch Hardware Installation Guide
Troubleshooting CSS Hardware Components
Recommended Action
Remove the module and re-install it to reseat the
module in the backplane connector.
Reload the ADI file.
Reload the ADI file.
Replace the module.
2-37

Advertisement

Table of Contents
loading

Table of Contents