Chapter 3
Configuring with the Command-Line Interface
Configuring an Analog Alarm as an Analog Monitoring Voltage
enable
config terminal
alarm 57
description "tank level"
description normal "full"
description low "low"
description low-low "empty"
analog voltage 2.5 30 60 60
exit
Configuring an Analog Alarm as a Discrete Monitoring Current
enable
config terminal
alarm 58
description "east door"
discrete current-loop 0.0 3.2 5.9
exit
Configuring an Analog Alarm as a Discrete Monitoring Voltage
enable
config terminal
alarm 58
description "backup battery"
discrete voltage 9.0 high
exit
Configuring an Analog Alarm to Act Like a Discrete Alarm (Minimal Configuration Method)
enable
config terminal
alarm 59
discrete
exit

Configuration Tasks

See the following sections for configuration tasks for the AIC feature. Each task in the list is identified
as either required or optional:
OL-1957-03
Configuring the AIC, page 3-38
Entering Alarm Configuration Mode and Configuring the AIC IP Address, page 3-38
Configuring the IP Route to the AIC, page 3-38
Configuring the NOC IP Address, page 3-40
Configuring Alarms, page 3-41
Software Configuration Guide for Cisco 2600 Series, Cisco 3600 Series, and Cisco 3700 Series Routers
Configuring the NM-AIC-64, Contact Closure Network Module
(required)
(optional)
(optional)
3-37