13: Advanced Parameters - FIBARO ROLLER SHUTTER 4 Operating Manual

Hide thumbs Also See for ROLLER SHUTTER 4:
Table of Contents

Advertisement

28
Switch type
Switch
Parametr (20)
Value
Name
Single
S1 or S2
4
bistable
switch
Single Click
Double Click
Command
ID
Command
ID
Window
Window
Covering
Covering
Id_Roller
Id_Roller
Start Level
Stop Level
Change
Change
13:
Advanced parameters
The device enables customizing its operation to a user's needs using
configurable parameters.
The settings can be adjusted using the Z-Wave controller to which the
device is added. The way of adjusting them might differ depending on the
controller.
In the NICE interface device configuration is available as a simple set of
options in the Advanced Settings section.
If you use Yubii Home App, many of the following parameter settings can
be changed in the device settings section.
To configure the device:
1. Go to Settings
.
2. Go to Devices.
3. Select the relevant device from the list.
4. Select the Parameters tab.
5. Specify a group and devices to associate with.
6. Save your changes.
Parameter
Description
Size
This parameter
determines which
20 – Switch
switch types and mode
1 [byte]
Type
S1 and S2 inputs
operate with.
24 –
This parameter enables
Buttons
reversing the operation
1 [byte]
orientation
of the buttons.
Default
Available
Value
Values
0 - Monostable
switches – click to
move
1 - Monostable
switches – hold to
move
0 (default
2 - Single monostable
value)
switch
3 - Bistable switches
4 - Single bistable
switch
5 - Three-state switch
0 – default (1
button
st
UP, 2
button DOWN)
nd
0 (default
1 – reversed (1
st
value)
button DOWN, 2
nd
button UP)
29