Table of contents 1: Important safety information 1: Important safety information Read this manual before attempting to install the device! 2: Description and features Failure to observe recommendations included in this manual can be dangerous or cause a violation of the law. The manufacturer, Nice-Polska 2.1: Description Sp.
Power supply 100 - 240 V~ 50/60 Hz Rated load current 2 A for motors with compensated power FIBARO ROLLER SHUTTER 4 is designed to control roller blinds, awnings, factor (inductive loads) venetian blinds, curtains and pergolas. Compatible load types...
4: Installation Installation: 1. Switch off the mains voltage (disable the fuse). 2. Open the wall switch box. 4.1: Before installation 3. Connect following the diagram below: Connecting the device in a manner inconsistent with this manual can cause risk to health, life or material damage. •...
5: Adding to the Z-Wave network 6: Removing from the Z-Wave network Adding (Inclusion) – the Z-Wave device learning mode enabling you to add Removing (Exclusion) – the Z-Wave device learning mode enabling you the device to the existing Z-Wave network. to remove the device from the existing Z-Wave network.
7: Calibration 2. if the calibration is still unsuccessful, decrease the value of parameter 155 to 1 W before trying to perform the calibration again. Calibration is a process during which the device learns the position of the limit switches and a motor characteristic. 3.
8: Operating the device Monostable switches - hold to move Example of the switch design: The device enables connecting switch to the S1 and S2 terminals. These can be monostable or bistable switches. Switch buttons are responsible for managing the blind movement. Description: –...
Page 8
Monostable switches - hold to move Single monostable switch Example of the switch design: Example of the switch design: Available Available Parameter Devices Description Parameter Devices Description values values Roller 1 – single This parameter determines Roller 1 - monostable This parameter determines blind, monostable...
Page 9
Bistable switches Single bistable switch Example of the switch design Example of the switch design Available Available Parameter Devices Description Parameter Devices Description values values 3 – bistable This parameter determines Roller 4 – single This parameter determines Roller switches which mode S1 or S2 inputs blind, bistable switch...
Page 10
Favorite position Three-state switch Your device has a built-in mechanism for setting favorite positions. Example of the switch design: You can activate it by double-clicking on the monostable switch(es) connected to the device or from the mobile interface (mobile App). Favorite roller blind position You can define the favorite position of the blinds.
9: Menu 10: Resetting the device to factory defaults Menu enables to perform the Z-Wave network actions. The reset procedure enables you to restore the device back to its factory settings, which means all information about the Z-Wave controller and a To use the menu: user's configuration is deleted.
11: Energy metering 12: Configuration The device enables the energy consumption monitoring. Data is sent to the Association (linking devices) – direct control of other devices within the main Z-Wave controller. Z-Wave system network. Measuring is carried out by the most advanced micro-controller technology, Associations enable: assuring maximum accuracy and precision (+/- 5% for loads greater than •...
Page 13
Association Group 2: Group Profile Command Class & Command Group Name Window Covering calibration status and command Id value. COMMAND_CLASS_DEVICE_ Window RESET_LOCALLY [0x5A] Window Covering Calibration status Covering name DEVICE_RESET_LOCALLY_ NOTIFICATION [0x01] Device is not OUT_BOTTOM_1 12 (0x0C) COMMAND_CLASS_WINDOW_ calibrated COVERING [0x6A] Autocalibration OUT_ BOTTOM _2...
Page 14
Operating mode: Switch type Switch Single Click Double Click Venetian blind 90° (param 151 = 1) or Parametr (20) Value Name Command Command Venetian blind 180° (param 151 = 2) Monostable Window switches – Switch type Covering click to move Switch Single Click Double Click...
Advanced parameters Switch type Switch Single Click Double Click Parametr (20) The device enables customizing its operation to a user’s needs using Value Name Command Command configurable parameters. Window Window Single S1 or S2 The settings can be adjusted using the Z-Wave controller to which the Covering Covering bistable...
Page 16
Default Available Default Available Parameter Description Size Parameter Description Size Value Values Value Values The parameter should This parameter enables 0 - default (O1 – UP, be modified only when reversing the operation 25 – O2 – DOWN) using electric curtains of O1 and O2 without 0 (default 154 - Delay...
14: Z-Wave Specification Default Available Parameter Description Size Value Values Indicator CC - available indicators This parameter enables you to set a Indicator ID – 0x50 (Identify) 158 – Virtual fixed minimum level of limit switch. 0 (default lowering the shutter. 1 [byte] 0-99 Indicator CC - available properties...
Page 18
Supported Command Classes Basic CC Mapping Command Class Version Secure Value Mapping command Command value COMMAND_CLASS_APPLICATION_STATUS [0x22] [0xFF] Multilevel Switch Set [0xFF] Basic Set COMMAND_CLASS_ZWAVEPLUS_INFO [0x5E] COMMAND_CLASS_WINDOW_COVERING [0x6A] Multilevel [0x00] Multilevel Switch Set Basic Set COMMAND_CLASS_SWITCH_MULTILEVEL [0x26] Switch Set COMMAND_CLASS_ASSOCIATION [0x85] [0x00] Start Level Change COMMAND_CLASS_MULTI_CHANNEL ASSOCIATION...
Page 19
Protection CC Altering capabilities Protection Command Class enables you to prevent local or remote control FIBARO Roller Shutter 4 uses different set of Window Covering of the outputs. Parameter IDs, which depend on the values of 2 parameters: • Calibration status (parameter 150) •...
NOTIFICATION [0x5A 0x01] in compliance with Directives 2014/53/EU and 2011/65/EU, 2015/863.The full text of the EU declaration of conformity NOTIFICATION_REPORT [0x71 0x05] is available at the following internet address: www.manuals. SWITCH_MULTILEVEL_REPORT [0x26 fibaro.com 0x03] General: WINDOW_COVERING_REPORT [0x6A Lifeline WEEE Directive Compliance:...