1-4 Installing the Intelligent Cameras

1-4
Installing the Intelligent Cameras
1-4-1
Optical chart
ZFX-SR50
Setting distance L (mm)
300
194
100
38
30
ZFX-SC90/SC90W
Setting distance L (mm)
160
142
100
67
40
40
10
Setting distance (L)
Detection range (H)
9
9.8
Detection range H (mm)
70
49
Detection range H (mm)
Note • The lens has a fixed focal point. The actual detection range and focal point
vary from lens to lens, so adjust the distance to the measurement target
after replacing the lens or camera.
• The camera mounting distance listed in the following tables is an approxi-
mate value. Mount the Camera so that the distance to the measurement
target can be adjusted easily.
• If the object size and detection range are incompatible, use a combination
of a camera (without lighting), standard CCTV lens and light source.
ZFX-SC10/SR10
Setting distance L (mm)
60
50
49
34
0
4
ZFX-SC50/SC50W
Setting distance L (mm)
190
187
100
31
30
60
49
9.8
ZFX-SC150/SC150W
Setting distance L (mm)
240
227
180
115
100
80
100
89
89
Preparation
4.9
8.9
Detection range H (mm)
Detection range H (mm)
120
148
Detection range H (mm)
10
49
160