Setting about Individual Data (Serial / SD-Card) [Binary Format]
<Measurement value of data 0 x 1000> <Measurement value of data 1 x 1000> ... <Measurement value of data 31 x 1000>
<Measurement value of data 0 x 1000> <Measurement value of data 1 x 1000> ... <Measurement value of data 31 x 1000>
MENU mode - [System] - [Output] - [Date format (Serial)/(SD Card)]
Setup Item
Output form
Display at time
File name
Output format
The value by 1000 times is output continuously as 4 bytes per single data
item. Minus number are output as 2' s complement.
4 bytes
Example: When data 0 is "256.324" and data 1 is "-1.000"
$00
$03
$E9
$44
$FF
$FF$FC $18
Data 0: 256324
Data 1: -1000
(256.324 x 1000)
When "Display at time" is ON, the time information is prefixed.
4 bytes
Example: When data 0 is "256.324" and data 1 is "-1.000"
$00
$03
$E9
$44
$FF
$FF$FC $18
Data 0: 256324
Data 1: -1000
(256.324 x 1000)
Run-Mode Measurement Process
Description
Selects binary.
Prefixes the output data with time information.
Range: OFF (default value), ON
Sets the name of the output file. (only when SD card is selected)
4 bytes
(-1.000 x 1000)
4 bytes
(-1.000 x 1000)
4 bytes
4 bytes