Multi-Function Output Terminal Contact Selection - Omron JX User Manual

200 v class three-phase input 0.2 to 7.5 kw; 200 v class single-phase input 0.2 to 2.2 kw; 400 v class three-phase input 0.4 to 7.5 kw
Table of Contents

Advertisement

Original signal waveform
(without delay)
ON delay only
OFF delay only
ON and OFF delays

Multi-function Output Terminal Contact Selection

This function allows you to set either contact for the two multi-function output terminals respectively.
Parameter No.
Function name
Multi-function output
C031
terminal 11 contact
selection
Relay output (AL2, AL1)
C036
contact selection
OFF delay
ON delay
Data
00: NO contact
01: NC contact
00: NO contact between AL2 and AL0
01: NC contact between AL2 and AL0
4-2 Function Mode
ON delay
OFF delay
Default setting
00
01
4
Unit
4-61