Omron CJ1W-EIP21 - 10-2010 Operation Manual page 422

Ethernet/ip units
Table of Contents

Advertisement

FINS Commands Addressed to EtherNet/IP Units or Built-in EtherNet/IP Ports
Response Codes
Response code
0000
Normal end
1001
Command too large
CONTROLLER STATUS READ
Reads the controller status.
Command Block
06 01
Command code
Response Block
06 01
Command
Response
Communications
code
code
Parameters
Communications Status 3 (Response)
15
14
13
12
11
10
Ethernet Basic Setting Error
Bit 2
0
No error
1
An error (such as an invalid IP address) was detected during the validity check of parameters related to the
TCP/IP Interface Object and Ether Link Object.
IP Address Table Error
Bit 3
0
No error
1
Error detected (More than 32 records, invalid IP address, or invalid FINS node address).
394
Description
2 byte
4 byte
4 byte
4 byte
Total number
Total number
Total number
status 3
of
of
packets received
receive errors
packets sent
9
8
7
6
5
4
3
4 byte
4 byte
Total number
Total number
of
of
of
send errors
send collisions
2
1
0
Bit 2: EtherNet/IP basic setting error
Bit 3: IP address table error
Bit 4: IP router table error
Bit 5: DNS server error
Bit 6: Routing table error
Bit 9: EtherNet/IP advanced setting error
Bit 10: BOOTP server error
Bit 11: SNTP server error
Bit 14: Address mismatch
Bit 15: Non-volatile memory error
Meaning
Meaning
Appendix E

Advertisement

Table of Contents
loading